|
Cover |
I |
|
Table of contents |
II |
|
Index |
2 |
|
Alphabetical index |
2 |
|
Catalogue number index |
16 |
|
Presentation |
28 |
|
General presentation |
28 |
|
IEC 61439 standard |
46 |
|
Determining catalogue numbers |
50 |
|
Prisma P functional system |
53 |
|
Circuit breakers |
56 |
|
Presentation of Masterpact NW/NT circuit breaker |
56 |
|
Masterpact NW08 to 32 |
57 |
|
Cables connection |
57 |
|
Canalis connection |
58 |
|
Masterpact NW08 to NW40 |
59 |
|
Dedicated cubicle |
59 |
|
Partial front plate support frames |
61 |
|
Masterpact NT06 to NT16 |
62 |
|
Toggle and motor mechanism - Cables connection |
62 |
|
Toggle and motor mechanism - Canalis connection |
63 |
|
Dedicated cubicle 3P |
64 |
|
Compact NS1600b to 3200 |
67 |
|
Cables connection |
67 |
|
Compact NS630b to NS1600 |
68 |
|
Vertical mounting with cable |
68 |
|
Canalis vertical mounting |
69 |
|
Compact NS630b to NS1000 |
70 |
|
Horizontal mounting |
70 |
|
Compact NS630b/1600 |
71 |
|
Dedicated cubicle |
71 |
|
Presentation of Compact NSX circuit breakers for Prisma P |
74 |
|
Compact NSX100 to NSX630 |
75 |
|
Horizontal mounting - Toggle - Fixed |
75 |
|
Horizontal mounting - Toggle - Plug-in |
76 |
|
Compact NSX100 to NSX250 |
77 |
|
Vertical mounting - Toggle - Fixed |
77 |
|
Compact NSX400 to NSX630 |
78 |
|
Vertical mounting - Toggle - Fixed |
78 |
|
Compact NSX100 to NSX250 |
79 |
|
Vertical mounting - Toggle - Plug-in |
79 |
|
Compact NSX400 to NSX630 |
80 |
|
Vertical mounting - Toggle - Plug-in |
80 |
|
Compact NSX100 to NSX630 |
81 |
|
Horizontal mounting - Rotary handle, motor mechanism - Fixed |
81 |
|
Horizontal mounting - Rotary handle, motor mechanism - Plug-in |
82 |
|
Compact NSX100 to NSX250 |
83 |
|
Vertical mounting - Rotary handle, motor mechanism - Fixed |
83 |
|
Compact NSX400 to NSX630 |
84 |
|
Vertical mounting - Rotary handle, motor mechanism - Fixed |
84 |
|
Compact NSX100 to NSX250 |
85 |
|
Vertical mounting - Rotary handle, motor mechanism - Plug-in |
85 |
|
Compact NSX400 to NSX630 |
86 |
|
Vertical mounting - Rotary handle, motor mechanism - Plug-in |
86 |
|
Horizontal mounting - All controls - Withdrawable |
87 |
|
Vertical mounting - All controls - Withdrawable |
88 |
|
Vertical mounting - All controls - Fixed/Plug-in |
89 |
|
Easypact CVS100/630 horizontal fixed mounting |
90 |
|
Toggle |
90 |
|
Rotary handle |
91 |
|
Easypact CVS100/630 vertical fixed mounting |
92 |
|
Toggle |
92 |
|
Rotary handle |
93 |
|
Fixed, toggle |
94 |
|
Switch disconnectors |
95 |
|
Compact INS-INV630b to 1600 Compact INS-INV2000-2500 |
95 |
|
Compact INS-INV250 to 630 |
96 |
|
Horizontal / Vertical - Front handle |
96 |
|
Modular devices |
97 |
|
Acti 9 |
97 |
|
Modular devices Acti 9 < 63 A |
98 |
|
Modular devices 80/160 A switchboard incomer |
99 |
|
Source-changeover |
100 |
|
Source-changeover, Compact / Masterpact |
100 |
|
Possible combinations, Compact NSX100/630, NS630b/1600, Masterpact NT06/16, NW08/32 |
101 |
|
Manual or remote-operated or automatic source-changeover |
102 |
|
Masterpact NW08/32, front connection S1 device identical to S2 device |
102 |
|
Masterpact NW08/32, rear connection S1 device identical to S2 device |
103 |
|
Masterpact NW08/32, front connection S1 device different to S2 device |
104 |
|
Masterpact NW08/32, rear connection S1 device different to S2 device |
105 |
|
Masterpact NT06/16, front connection S1 device identical to S2 device |
106 |
|
Masterpact NT06/16, rear connection S1 device identical to S2 device |
107 |
|
Masterpact NT06/16, front connection S1 device different to S2 device |
108 |
|
Compact NS630b to 1000 |
109 |
|
Manual source-changeover |
110 |
|
Compact NSX100/630 |
110 |
|
Remote-operated source-changeover |
111 |
|
Compact NSX100/630 |
111 |
|
Manual source-changeover |
112 |
|
Compact INS-INV250 to 630 Front direct rotary handle |
112 |
|
Compact INS250 to 630 Complete assembly device |
113 |
|
Fusegear |
114 |
|
Fupact presentation |
114 |
|
Fupact ISFL |
115 |
|
Vertical / 3P - Determining the busbars |
115 |
|
Fupact ISFT |
116 |
|
Vertical / 3P - Installation on mounting plate or busbars, Determining the busbars |
116 |
|
Fupact INF |
117 |
|
Horizontal / Vertical - Extended rotary handle |
117 |
|
Others |
118 |
|
Power factor correction equipment |
118 |
|
Industrial control devices |
120 |
|
Metering |
121 |
|
3-phase kilowatt-hour meters |
121 |
|
Single-phase and 3-phase kilowatt-hour meters Class 2 |
122 |
|
Human-switchboard interface |
123 |
|
72 x 72 and 96 x 96 mm devices |
123 |
|
Reserve space |
126 |
|
Fixing accessories |
127 |
|
Universal adapter |
128 |
|
Prisma G adapter - Mounting on a plain backplate |
128 |
|
Mounting on a slotted plate - Mounting on a modular rail |
129 |
|
Cable running |
130 |
|
Connection accessories |
131 |
|
Cable-tie supports, lateral and longitudinal cross-members |
131 |
|
Switchboard lighting |
132 |
|
Linergy distribution and connection systems |
135 |
|
Main distribution |
142 |
|
Busbars presentation Linergy LGYE 630 A to 4000 A |
142 |
|
Horizontal/vertical |
142 |
|
Horizontal and lateral busbars |
143 |
|
Linergy LGY busbars presentation |
144 |
|
Lateral busbars |
144 |
|
Linergy BS busbars presentation |
145 |
|
Horizontal and lateral busbars |
145 |
|
Power busbars |
146 |
|
Linergy LGYE |
146 |
|
Horizontal profiles up to 4000 A |
146 |
|
Linergy BS |
147 |
|
Horizontal busbars up to 4000 A |
147 |
|
Linergy LGY |
148 |
|
Lateral profiles up to 3200 A |
148 |
|
Linergy LGYE |
149 |
|
Lateral profiles up to 4000 A |
149 |
|
Linergy BS |
150 |
|
Lateral flat busbars up to 4000 A |
150 |
|
Linergy LGY |
151 |
|
Rear profiles up to 1600 A |
151 |
|
Linergy BS |
152 |
|
Rear busbars up to 1600 A |
152 |
|
Linergy - Accessories |
153 |
|
Linergy BW |
156 |
|
Insulated busbars up to 630 A |
156 |
|
Linergy BS |
158 |
|
Rear busbars up to 400 A |
158 |
|
Multi-stage busbars up to 630 A |
159 |
|
Multi-stage distribution block up to 630 A |
160 |
|
Incomer accessories up to 630 A |
161 |
|
Linergy DP quick distribution blocks |
162 |
|
Linergy FC feeders for compact NSX & INS |
164 |
|
Linergy DX quick distribution blocks |
168 |
|
Linergy FM quick device feeders |
170 |
|
Linergy DS screw distribution blocks |
172 |
|
Linergy FH |
174 |
|
Comb busbar for 27 mm pitch for C120, NG125 |
174 |
|
Comb busbar for 18 mm pitch for Acti 9 |
175 |
|
Comb busbar for 9 mm pitch for Acti 9, C60 |
177 |
|
Horizontal comb busbar for 18 mm pitch for Domae |
179 |
|
Horizontal biconnect comb busbar for 18 mm pitch |
180 |
|
Terminal blocks and lines |
181 |
|
Linergy TA |
181 |
|
Auxiliary connections |
181 |
|
Linergy TB |
182 |
|
Earth bars |
182 |
|
PE conductor |
183 |
|
Secondary distribution |
184 |
|
Linergy TB terminal block support |
184 |
|
Linergy TR |
185 |
|
Introduction |
185 |
|
Terminal blocks |
186 |
|
Prisma functional system |
188 |
|
Main distribution |
189 |
|
Form 1 partitioning |
189 |
|
Covering the supply terminals on the incoming device |
190 |
|
Form 2 partitioning |
191 |
|
Form 3 partitioning |
193 |
|
Form 4 partitioning |
195 |
|
Other partitions |
197 |
|
Prisma P enclosures |
199 |
|
IP30/31/55 cubicles - Presentation |
200 |
|
Cover panels |
206 |
|
Cubicles |
209 |
|
Frameworks |
209 |
|
IP30/31 cover panels |
211 |
|
IP55 cover panels |
213 |
|
Plinth |
215 |
|
Cubicle handling and rolling base, lifting reinforcement kit, right-angle kit |
216 |
|
Installation accessories |
217 |
|
Front plate accessories |
218 |
|
Enclosure accessories |
219 |
|
Door handles and locks |
219 |
|
Air-conditioning accessories |
220 |
|
Ventilation |
220 |
|
Heat |
224 |
|
Regulating |
225 |
|
Dimensions |
226 |
|
Additional information |
235 |
|
After-sales support |
237 |
|
The energy management with Prisma P |
241 |
|
Introduction |
241 |
|
Presentation |
242 |
|
Functional units |
244 |
|
Energy efficiency with Prisma P |
246 |
|
Optimise electrical networks |
246 |
|
Improving power quality |
246 |
|
Additional equipment to optimise electrical installations |
247 |
|
Electrical characteristics |
248 |
|
Designing Prisma P power circuits |
248 |
|
Presentation and approach |
248 |
|
Designing horizontal busbars |
251 |
|
Linergy LGYE |
251 |
|
Linergy BS |
252 |
|
Designing vertical busbars |
253 |
|
Linergy LGY |
253 |
|
Linergy LGYE |
254 |
|
Linergy BS |
255 |
|
Designing rear busbars |
256 |
|
Linergy LGYE, Linergy BS |
256 |
|
Designing connections between a device and busbars |
257 |
|
Prefabricated connections for Compact NS630b to NS1600 |
257 |
|
Prefabricated connections for Masterpact NT06 to NT16 |
258 |
|
Prefabricated connections for Compact NS630b to NS1000 |
259 |
|
Fixed Masterpact NW08 to NW16 |
260 |
|
Fixed Masterpact NW08 to NW32 |
261 |
|
Drawout Masterpact NW08 to NW16 |
262 |
|
Drawout Masterpact NW08 to NW32 |
263 |
|
Dedicated cubicle - Fixed Masterpact NW08 to NW32 |
264 |
|
Dedicated cubicle - Drawout Masterpact NW08 to NW32 |
265 |
|
Fixed Masterpact NT06 to NT16 |
266 |
|
Drawout Masterpact NT06 to NT16 |
268 |
|
Fixed Compact NS1600b to NS3200 |
270 |
|
Fixed Compact NS630b to NS1600 |
271 |
|
Withdrawable Compact NS630b to NS1600 |
273 |
|
Horizontal, fixed Compact NS630b to NS1000 |
275 |
|
Designing connections < 630 A |
276 |
|
Device connections |
276 |
|
Compact circuit breakers NSX100 to NSX630 Insulated flexible copper bars |
277 |
|
Compact circuit breakers NSX100 to NSX630 Copper cable |
278 |
|
Designing cable connections |
279 |
|
Tubular lugs |
279 |
|
Designing customer connections |
280 |
|
Prefabricated connections for Compact NS630b to NS1600 |
280 |
|
Prefabricated connections for Masterpact NT06 to NT16 |
281 |
|
Connection transfer assembly for fixed Compact NS630b to NS1000 |
282 |
|
Fixed Masterpact NW08 to NW16 |
283 |
|
Fixed Masterpact NW08 to NW40 |
284 |
|
Drawout Masterpact NW08 to NW16 |
285 |
|
Masterpact NW08 to NW40 withdrawable |
286 |
|
Fixed Masterpact NT06 to NT16 |
287 |
|
Drawout Masterpact NT06 to NT16 |
288 |
|
Fixed Compact NS1600b to NS3200 |
289 |
|
Fixed Compact NS630b to NS1600 |
290 |
|
Withdrawable Compact NS630b to NS1600 |
291 |
|
Fixed Compact NS630b to NS1000 Horizontal mounting |
292 |
|
Designing busbars |
293 |
|
Fupact INF, ISFT, ISFL - Horizontal Linergy LGYE busbars |
293 |
|
Fupact INF, ISFT, ISFL - Linergy BS busbars |
294 |
|
Fupact INF, ISFT - Vertical Linergy LGYE, LGY busbars |
295 |
|
Fupact INF, ISFT - Vertical Linergy BS busbars |
296 |
|
Standards and tested switchboards |
297 |
|
Enclosure characteristics |
302 |
|
Selection of enclosures according to the premises |
302 |
|
Properties of metal enclosures |
309 |
|
Thermal characteristics of switchboards |
311 |
|
Thermal management of switchboards |
311 |
|
General |
311 |
|
Example |
314 |
|
Charts |
316 |
|
Ventilation |
317 |
|
Heating |
318 |
|
Practical information |
319 |
|
Tools required for mounting and connection |
319 |
|
Connection of horizontal to vertical busbars |
320 |
|
Installation of the current transformer |
321 |
|
Installation of source changeover systems |
323 |
|
Storage recommendations |
325 |
|
Packing information |
326 |
|
Handling on the site |
327 |
|
Transport |
329 |
|
Cubicle handling and rolling base |
330 |
|
Lifting reinforcement kit for combined cubicles |
330 |
|
Connection of busbar trunking |
331 |
|
Connection of power cables |
332 |
|
Maintenance |
335 |
|
Preventive maintenance |
335 |
|
Corrective maintenance |
337 |


