Table of Contents Table of Contents
Previous Page  77 / 338 Next Page
Information
Show Menu
Previous Page 77 / 338 Next Page
Page Background

A-25

Circuit breakers

Functional system

Functional units

Compact NSX100 to NSX250

vertical mounting

Toggle

Fixed

Mounting

Vertical fixed

650 150

400

DD380506.eps

Devices

Toggle

NSX100/160

Vigi NSX100/160

NSX250

Vigi NSX250

Number of devices per row

3/4

3/4

3/4

3/4

No. of vertical modules

(1)

6

8

7

9

Mounting plates

03420

03420

03420

03420

Front plates

[No. of vertical modules]

with cut-out

03243

[5]

03241

[7]

03243

[5]

03241

[7]

downstream

03801

[1]

03801

[1]

03802

[2]

03802

[2]

(1)

For the Compact NSX100/250, the number of modules indicated is for supply via a Linergy FC distribution block.

For supply via cables, two additional modules are required; add an upstream plain front plate (03802).

Connection

Distribution via lateral busbars

Linergy LGY

DD380508.eps

Devices

Toggle

NSX100/160, Vigi NSX100/160

NSX250, Vigi NSX250

3P

4P

3P

4P

Number of devices per row

4

3

4

3

Linergy FC distribution blocks (with connection)

04403

04404

04403

04404

Linergy BS, LGYE

Devices

Toggle

NSX100/160, Vigi NSX100/160

NSX250, Vigi NSX250

3P

4P

3P

4P

Number of devices per row

4

3

4

3

Linergy FC distribution blocks (without connection)

04407

04408

04407

04408

Devices

Toggle

NSX100/160, Vigi NSX100/160

NSX250, Vigi NSX250

3P

4P

3P

4P

Number of devices per row

4

3

4

3

Front connection

with cable

(1)

long terminal shields

LV429517

LV429518

LV429517

LV429518

Rear connection

with cable

short terminal shields

LV429515

LV429516

LV429515

LV429516

short rear connectors

LV429235

LV429235

long rear connectors

LV429236

LV429236

Accessories

Linergy FC tooth-caps

04809

Divisible blanking plate

03249

Divisible blanking plate + electronic trip unit

03222

(1)

For the Compact NSX100/250, the number of modules indicated is for supply via a Linergy FC distribution block.

For supply via cables, two additional modules are required; add an upstream plain front plate (03802).

Distribution

Downstream in cubicle

DD380696.eps

Devices

Toggle

NSX100/160, Vigi NSX100/160

NSX250, Vigi NSX250

3P

4P

3P

4P

Front connection long terminal shields

LV429517

LV429518

LV429517

LV429518

Rear connection

(2)

short terminal shields

LV429515

LV429516

LV429515

LV429516

short rear connectors

LV429235

LV429235

long rear connectors

LV429236

LV429236

(2)

Size reduced one module downstream.