A-36

Circuit breakers

Functional system

Functional units

Mounting

Vertical withdrawable

650 150

400

Dd383574.eps

Devices

All controls

NSX100/160 NSX250 NSX400 NSX400

toggle

NSX400

rotary handle

+ motor

mechanism

NSX630 NSX630

toggle

NSX630

rotary handle

+ motor

mechanism

Number of devices per row 2

2

2

1

1

2

1

1

No. of vertical modules

8

9

11

11

11

13

13

13

Mounting plates

03421

03421

03461

(2)

03461

03461

(2)

03461

(2)

03461

03461

(2)

Front plates

[No. of vertical

modules]

upstream

03802

[2]

03802

[2]

03802

[2]

03801

[1]

03801

[1]

03803

[3]

03802

[2]

03802

[2]

with cut-out

03243

[5]

03243

[5]

03663

[7]

03275

[9]

03275

[9]

03663

[7]

03275

[9]

03275

[9]

downstream

03801

[1]

03802

[2]

03802

[2]

03801

[1]

03801

[1]

03803

[3]

03802

[2]

03802

[2]

Collar

LV429284

(1)

LV429284

(1)

LV432534

(1)

LV432534 -

LV432534

(1)

LV432534 -

Mounting

Vertical withdrawable

650 150

400

Dd383574.eps

Devices

All controls

Vigi

NSX100/160

Vigi NSX250 Vigi NSX400

toggle

Vigi NSX400

rotary handle +

motor mechanism

Vigi NSX630

toggle

Vigi NSX630

rotary handle +

motor mechanism

Number of devices per row 2

2

1

2

1

2

1

2

1

2

No. of vertical modules

10

11

13

13

15

15

Mounting plates

03421

03421

03461 03461 03461 03461 03461 03461 03461 03461

Front plates

[No. of vertical

modules]

upstream

03802

[2]

03802

[2]

-

03802

[2]

-

03802

[2]

03801

[1]

03803

[3]

03801

[1]

03803

[3]

with cut-out

03244

[7]

03244

[7]

03297

[11]

03666

[9]

03297

[11]

03666

[9]

03297

[11]

03666

[9]

03297

[11]

03666

[9]

downstream

03801

[1]

03802

[2]

03802

[2]

03802

[2]

03802

[2]

03802

[2]

03803

[3]

03803

[3]

03803

[3]

03803

[3]

Collar

LV429285

+

LV429284

(1)

LV429285

+

LV429284

(1)

LV429285

+

LV432534

(1)

LV429285

LV429285

+

LV432534

LV429285

(1)

For devices with toggle only.

(2)

Catalogue number 03460 is recommended when installing an NSX with a motor mechanism.

Connection

Distribution via lateral busbars

Linergy LGY, Linergy BS, LGYE

Devices

Withdrawable device

NSX100/250, Vigi NSX100/250

NSX400/630, Vigi NSX400/630

3P

4P

3P

4P

Number of devices per row 2

1/2

Front

conn.

connection

must be made with insulated flexible bars, see page B-32.

long terminal shields

LV429517

LV429518

LV432593

LV432594

short terminal shields

LV429515

LV429516

LV432591

LV432592

connection adapter for

plug-in base

LV429306

LV429307

LV432584

LV432585

Rear

conn.

short terminal shields 2 x

LV429515

2 x

LV429516

2 x

LV432591

2 x

LV432592

short rear connectors

LV429235

LV429235

LV432475

LV432475

long rear connectors

LV429236

LV429236

LV432476

LV432476

connection adapter for

plug-in base

LV429306

LV429307

LV432584

LV432585

Distribution

Downstream in cubicle

Dd383575.eps

Devices

Vertical withdrawable

NSX100/250, Vigi NSX100/250

NSX400/630, Vigi NSX400/630

3P

4P

3P

4P

Front

conn.

connection adapter

for plug-in base

LV429306

LV429307

LV432584

LV432585

short terminal shields

on device

LV429515

LV429516

LV432591

LV432592

long terminal shields

on plug-in base

LV429517

LV429518

LV432593

LV432594

Rear

conn.

short terminal shields 2 x

LV429515

2 x

LV429516

2 x

LV432591

2 x

LV432592

short rear connectors

LV429235

LV429235

LV432475

LV432475

long rear connectors

LV429236

LV429236

LV432476

LV432476

connection adapter

for plug-in base

LV429306

LV429307

LV432584

LV432585

Compact NSX100 to NSX630

vertical mounting

All controls

Withdrawable