![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0052.jpg)
50
Starting with the electrical
diagram: IP30 switchboard
NSX250 NSX250 NSX250
NS1000
INS
GV2
C60
or
IC60
C60
or
IC60
DD384077.eps
Install the incomer
Front conn. using cables
Device
NS630b/1000
NS1250/1600
Arc chute screen
3P
33596
4P
33597
Vertical connection
adapters
3P
33642
4P
33643
Front connection cover
04851
Fixed device
DD385547EN.eps
See page A-16
DD380878.eps
Dd380822.eps
Order
b
b
connection
components
b
b
mounting plates and
front plates
b
b
busbar connections.
Device installation
Device
NS630b/1000
NS1250/1600
Number of devices per row
1
1
No. of vertical modules
12
14
Mounting plates
03482
03482
Front plates
[No. of vertical
modules]
upstream
03802
[2]
03804
[4]
with cut-out
03690
or
03701
[7]
downstream
03803
[3]
03803
[3]
Mounting
Front connection with cables
Fixed device
DD385548EN.eps
DD380870.eps
Linergy LGY BB conn.
Device
NS630b/1250
NS1600
connection type
Front connectiondelivered with the device
Busbars connection
For Linergy LGY busbars: prefabricated connection
3P
04485
04487
4P
04486
04488
Cover for busbars connection
Linergy LGY,LGYE,BS
04926
Fixed device
DD385549EN.eps
DD380871.eps
Install the Compact devices
Installation
Device
Toggle
NSX100/250, Vigi NSX100/250
3P
4P
Number of devices per row
1
1
No. of vertical modules
3
4
Mounting plates
03411
03412
Front plates
with cut-out
03604
[3]
03606
[4]
[No. of vertical modules]
DD385550EN.eps
See page A-23
DD383867.eps
Dd380823.eps
Order
b
b
mounting plates and
front plates
b
b
busbar connections
b
b
connection
accessories.
Linergy LGY BB conn.
LinergyLGY
Device
Toggle
NSX100/250, Vigi NSX100/250
3P
4P
Prefabricated connection
04423
04424
DD385551EN.eps
DD380873.eps
Connection
Device
Toggle
NSX100/160
Vigi NSX100/160
NSX250
Number of devices per row 3/4
3/4
3/4
No. of vertical modules
6
8
7
Mounting plates
03420
03420
03420
Front plates
[No. of vert. mod.]
with cut-out
03243
[5]
03241
[7]
03243
[5]
downstream
03801
[1]
03801
[1]
03802
[2]
DD385552EN.eps
DD380874.eps
See page A-25
Dd380824.eps
Order
b
b
mounting plates and
front plates
b
b
distribution block
b
b
connection
accessories.
Installation
Device
Toggle
NSX100/160
NSX250
Number of devices per row
3/4
3/4
3/4
3/4
No. of vertical modules
6
8
7
9
Mounting plates
03420
03420
03420
03420
Front plates
[No. of vert. mod.]
with cut-out
downstream
03243
[5]
03241
[7]
03243
[5]
03241
[7]
03801
[1]
03801
[1]
03802
[2]
03802
[2]
Vigi NSX100/160
Vigi NSX250
DD385553EN.eps
DD380875.eps
Linergy LGY BB conn.
LinergyLGY
NSX100/160, Vigi NSX100/160 NSX250, Vigi NSX250
3P
4P
3P
4P
Number of devices
4
3
4
3
Linergy FC distribution blocks
(with connection)
04403
04404
04403
04404
Device
Toggle
DD385554EN.eps
DD380876.eps
Connection
Device
Toggle
NSX100/160, Vigi NSX100/160 NSX250, Vigi NSX250
3P
4P
3P
4P
Front connection
long terminal shields
LV429517
LV429518
LV429517
LV429518
Rear connection
short terminal shields
LV429515
LV429516
LV429515
LV429516
DD385555EN.eps
DD380877.eps
1
2
3
1
2
3
1
2
3
Determining catalogue numbers
Cat. no. selection
Determining cat. no.
and configuration assistance