Table of Contents Table of Contents
Previous Page  62 / 338 Next Page
Information
Show Menu
Previous Page 62 / 338 Next Page
Page Background

A-10

Mounting

Front connection with cables

650 150

400

Dd380794.eps

Devices

Fixed device

Withdrawable device

NT06/10

NT12/16

NT06/10

NT12/16

Number of devices per row

1

1

1

1

No. of vertical modules

12

14

13

15

Mounting plates

03484

03484

03483

03483

Front plates

[No. of vertical

modules]

upstream

03802

[2]

03804

[4]

03802

[2]

03804

[4]

with cut-out

03692

[7]

03692

[7]

03691

[8]

03691

[8]

downstream

03803

[3]

03803

[3]

03803

[3]

03803

[3]

Mounting

Rear connection with cables

150

Dd380796.eps

Devices

Fixed device

Withdrawable device

NT06/16

NT06/16

Number of devices per row

1

1

No. of vertical modules

11

11

Mounting plates

03484

03483

Front plates

[No. of vertical

modules]

upstream

03801

[1]

-

with cut-out

03692

[7]

03691

[8]

downstream

03803

[3]

03803

[3]

Connection

Upstream on incomer

Devices

Fixed device

Withdrawable device

NT06/10

NT12/16

NT06/10

NT12/16

3P 4P 3P

4P

3P 4P 3P

4P

Type of terminals for front connection Front connections supplied with the device

for rear connection Vertical rear connections supplied with the device

Vertical connection adapters

33642

(2)

33643

(2)

33642

(2)

33643

(2)

33642

(2)

33643

(2)

33642

(2)

33643

(2)

Terminal extension bar support rear

connection

2 x

04693

Arc-chute cover

47335

47336 47335

47336

-

Connection block cable-lug adapters Direct

33644

(2)

33645

(2)

Direct

33644

(2)

33645

(2)

spacing rods

04691

04691

Cables cover

front connection

04852

rear connection

04854

(1)

Connection to be made according to the busbar drawings supplied by Schneider Electric.

Distribution

Downstream on Linergy LGY, LGYE or BS busbars

DD380648.eps

DD380649.eps

Devices

Fixed device

Withdrawable device

NT06/12

NT16

NT06/12

NT16

3P

4P

3P 4P 3P

4P

3P 4P

Type of terminals

Front connections supplied with the device

Busbars connection

For Linergy LGY busbars: prefabricated connection

04475

04476

04489 04490 04477

04478

04491 04492

must be made

(1)

.

For Linergy LGYE (see page B-19) and Linergy BS busbars

Free support for busbars connection 2 x

04662

Cover for busbars connection

04926

(1)

Connection to be made according to the busbar drawings supplied by Schneider Electric.

(2)

Vertical connection adapters and cable-lug adapters are not compatible with input voltage

u

500 V.

Note:

to make measurements:

b

install the CTs on the horizontal busbars (busbar connection); in this case, an additional module is required; add a plain front pla

te (03801)

or install a Micrologic

control unit capable of displaying the values.

Selection of Linergy LGY:

see page B-14,

Linergy LGYE:

see page B-15,

Linergy BS:

see page B-16.

Masterpact NT06 to NT16

Toggle and motor mechanism

Cables connection

Circuit breakers

Functional system

Functional units