Page Background

12/10

Total Solution to Earthing & Lightning Protection |

9AKK106354A3360

12

Combined Category D, C, B tested protector (to BS EN 61643) based on

the ESP D Series and ESP TN but ready-boxed to IP66 for use in damp or

dirty environments. Suitable for most twisted pair signalling applications.

Available for working voltages of up to 6, 15, 30, 50 and 110 Volts. ESP TN

suitable for Broadband, POTS, dial-up, T1/E1, lease line and *DSL telephone

applications. For use at boundaries up to LPZ

0

to protect against

flashover (typically the service entrance location) through to LPZ 3 to

protect sensitive electronic equipment.

Data & signal protection

ESP D/BX Series

A

LINE

CLEAN

LIGHTNINGBARRIER

ESP06D/BX

EARTH

STUD

A

B

B

DIRTY

CLEAN

To

equipment

From line

Earth

Install in series (in-line)

Features & benefits

–– Very low let-through voltage (enhanced protection to

IEC/BS EN 62305) between all lines - Full Mode protection

–– Full Mode design capable of handling partial lightning

currents as well as allowing continual operation of

protected equipment

–– Repeated protection in lightning intense environments

–– Low in-line resistance minimizes unnecessary reductions in

signal strength

–– Ready-boxed to IP66 and supplied ready for flat mounting

–– Available with screw terminals or with IDC terminals (by

adding /I suffix to part number)

–– Colour coded terminals for quick and easy installation

check - grey for the dirty (line) end and green for clean

–– Screen terminal enables easy connection of cable screen

to earth

–– Substantial earth stud to enable effective earthing

–– ESP TN/BX and ESP TN/2BX are suitable for

telecommunication applications in accordance with

Telcordia and ANSI Standards (see Application Note

AN005)

–– Supplied as standard with screw terminals - for IDC

terminals order part code plus /I (e.g. ESP TN/BX/I)

–– ESP TN/BX has Network Rail Approval PA05/02877.

NRS PADS reference 087/037286

Installation

Connect in series with the data communication, signal or

telephone line either near where it enters/leaves the building

or close to the equipment being protected. Either way, it must

be very close to the system’s earth star point.

Application

Use these ready-boxed protectors on twisted pair lines in dirty

or damp environments. For two wire lines, use /BX versions.

For four wire lines, use /2BX versions.

Full product range order codes can be found on pages 17/8-17/9

NOTE:

For installation in the equipment panel, protectors which are not boxed may be more suitable. If your system requires a protector with a very low resistance,

higher current or higher bandwidth use the ESP E or H Series. Unboxed protectors for 3-wire RTD systems are available - as are plug-in protectors for telephone

lines and compact Slim Line protectors.