12/6

Total Solution to Earthing & Lightning Protection |

9AKK106354A3360

12

Combined Category D, C, B tested protector (to BS EN 61643) suitable

for twisted pair signalling applications which require either a lower in-line

resistance, an increased current or a higher bandwidth than the ESP D Series.

Also suitable for DC power applications less than 1.25 Amps. Available for

working voltages of up to 6, 15, 30, 50 and 110 Volts. For use at boundaries up

to LPZ

0

to protect against flashover (typically the service entrance location)

through to LPZ 3 to protect sensitive electronic equipment.

Data & signal protection

ESP E Series

Installation

Connect in series with the data communication or signal line

either near where it enters or leaves the building or close to

the equipment being protected (e.g. within its control panel).

Either way, it must be very close to the system’s earth star

point. Install protectors either within an existing cabinet/

cubicle or in a separate enclosure.

Accessories

Combined Mounting/Earthing kits:

CME 4

Mount & earth up to 4 protectors

CME 8

Mount & earth up to 8 protectors

CME 16

Mount & earth up to 16 protectors

CME 32

Mount & earth up to 32 protectors

Weatherproof enclosures:

WBX 2/G

For use with up to 2 protectors

WBX 3, WBX 3/G

For use with up to 3 protectors

WBX 4, WBX 4/GS

For use with a CME 4 and up to 4

protectors

WBX 8, WBX 8/GS

For use with a CME 8 and up to 8

protectors

WBX 16/2/G

For use with one or two CME 16 and up to

32 protectors

Full product range order codes can

be found on pages 17/8-17/9

Install in series (in-line)

DIRTY

CLEAN

From line To equipment

Earth

Features & benefits

–– Very low let-through voltage (enhanced protection to

IEC/BS EN 62305) between all lines - Full Mode protection

–– Full Mode design capable of handling partial lightning

currents as well as allowing continual operation of

protected equipment

–– Repeated protection in lightning intense environments

–– Very low (1 Ω) in-line resistance allows resistance critical

applications (e.g. alarm loops) to be protected

–– High (1.25 A) maximum running current

–– High bandwidth enables higher frequency (high traffic or bit

rate) data communications

–– Screen terminal enables easy connection of cable screen

to earth

–– Strong, flame retardant, ABS housing

–– Built-in DIN rail foot for simple clip-on mounting to top hat

DIN rails

–– Colour coded terminals give a quick and easy installation

check - grey for the dirty (line) end and green for clean

–– Substantial earth stud to enable effective earthing

–– Supplied ready for flat mounting on base or side

–– Integral earthing plate for enhanced connection to earth

via CME kit

–– ESP 06E and ESP 15E have Network Rail Approval

PA05/02047. NRS PADS reference 086/000201 (ESP 06E)

and 086/000200 (ESP 15E)

Application

Use these units to protect resistance sensitive, higher

frequency or running current systems, e.g. high speed

digital communications equipment or systems with long

signal lines.

NOTE:

Slim Line (ESP SL), ATEX (ESP SLX) and PCB mount (ESP PCB) are available. For many twisted pair data and signal applications, the lower cost

ESP D Series may be suitable. For applications requiring higher current (1.25 A to 4 A) or ultra-low in-line resistance, the ESP H Series protectors may be