Table of Contents Table of Contents
Previous Page  92 / 210 Next Page
Information
Show Menu
Previous Page 92 / 210 Next Page
Page Background

92

Isolating and safety isolating <50 V transformers

Designed to meet the needs of users with specific VA ratings such as original equipment manufacturers

The terminals are designed to provide easy and quick connections

Transformers up to 160 VA can be clipped to

4

rail using accessory or directly fixed using screws through the easily accessible fixing points

Multiple fixing possibilities :

- clip to DIN rail using Cat. No. 0044 16 or 0428 99 (

160 VA)

- screw directly on to Lina 12 . 5 or Lina 25 mounting plate (

220 VA)

Recommended protection :

• for 40 and 63 VA : Type T fuses (5x20) time delay fuse to IEC 60127

• for >100 VA use MCB Type C

Pack

Cat. Nos.

Single phase

Safety isolating transformers

Primary : 230-400 V

Secondary : 12-24 V

Power in VA

Admissible

according to

instantaneous power

IEC/EN

at cos

ϕ

0·5

1

0428 40

40 VA

55

1

0428 41

63 VA

91

1

0428 42

100 VA

140

1

0428 43

160 VA

205

1

0428 44

220 VA

290

1

0428 45

310 VA

345

1

0428 47

630 VA

1 520

Primary : 230-400 V

Secondary : 24 V

Power in VA

Admissible

according to

instantaneous power

IEC/EN

at cos

ϕ

0·5

1

0428 55

40 VA

55

1

0428 56

63 VA

91

1

0428 57

100 VA

140

1

0428 58

160 VA

205

1

0428 59

220 VA

290

1

0428 60

310 VA

345

1

0428 61

450 VA

1 100

1

0428 62

630 VA

1 520

Safety isolating transformers

Primary : 230-400 V

Secondary : 24-48 V

Power in VA

Admissible

according to

instantaneous power

IEC/EN

at cos

ϕ

0·5

1

0428 70

40 VA

55

1

0428 71

63 VA

80

1

0428 72

100 VA

150

1

0428 73

160 VA

160

1

0428 74

220 VA

290

1

0428 75

310 VA

345

1

0428 77

630 VA

1 520

Accessories

Clips for fixing up to 160 VA

on to rail EN 60715

4

10

0044 16 Claw width 10 mm

Threaded hole for M4 screws

(Use two clips per transformer)

Mounting bracket

5

0428 99 DIN rail mounting bracket

Pack

Cat. Nos.

Single phase

Isolating transformers

Primary : 230-400 V

Secondary : 115 V

With centre tap

Power in VA

Admissible

according to

instantaneous power

IEC/EN

at cos 0·5

1

6423 62

63 VA

91

1

6423 63

100 VA

140

1

6423 64

160 VA

205

1

6423 65

220 VA

290

1

6423 66

310 VA

345

1

6423 68

630 VA

1 520

Isolating transformers

Primary : 230-400 V

Secondary : 115-230 V

Power in VA

Admissible

according to

instantaneous power

IEC/EN

at cos 0·5

1

0427 85

40 VA

55

1

0427 86

63 VA

91

1

0427 87

100 VA

140

1

0427 88

160 VA

205

1

0427 89

220 VA

290

1

0427 90

310 VA

345

1

0427 92

630 VA

1 520

Indice protection-1061s

Indice protection-1061s

Indice protection-1061s

006187-5342o.eps

Indice protection-1062.eps

Indice protection-1062.eps

0427 89

0427 92

0428 75

0428 41

supplied with connection strip

0428 99

Connection strip

supplied up to 450 VA

compact transformers

open type single phase

Technical information and dimensions

p. 93

Transformer protection

p. 95

Protection devices

p. 56-64

Modular transformers

p. 102