Background Image
Table of Contents Table of Contents
Previous Page  91 / 244 Next Page
Information
Show Menu
Previous Page 91 / 244 Next Page
Page Background

Pack

Cat. Nos.

Room controllers

Ability to connect the sensor(s) and the

push button(s)

Fixed directly to the false ceiling via cable ducting

Controller/sensor output connection

(up to 10 sensors Cat. Nos. 0488 20/21/22/23/24/30,

see opposite)

by cord or RJ 45 cable or BUS/SCS cable to be

fitted with RJ 45 connector Cat. No. 0488 72

Power supply 100/240 V

Room controller 2 outputs 16 A

1

0488 50 Allows 2 lighting circuits to be controlled in

2 different phases or 1 lighting circuit and 1 A/C

circuit

Room control 1 input, 2 outputs DALI/DSI

1

0488 51 Controller for DALI and DSI dimming

Enables the window side of a room (which benefits

from natural light) and the corridor (which has less

natural light) to be dimmed separately with a single

sensor

1 sensor input, 2 inputs for auxiliaries,

2 DALI outputs and 1 fan output (volt-free contact)

For controlling light sources with sensors (with up to

5 sensors) :

- 2 x 16 DALI/DSI ballasts

Connected via screw terminals

Room control 1 input, 2 outputs 1-10 V

1

0488 52 Dimming lighting controller 1-10 V

Enables the window side of a room (which benefits

from natural light) and the corridor (which has less

natural light) to be dimmed separately with a single

sensor

1 sensor input, 2 inputs for auxiliaries and

2 lighting outputs

Connected via screw terminals

0488 50

Automatic lighting management in areas that benefit from natural light : e.g. individual and open-plan offices, meeting rooms + Management of an

additional circuit - lighting/air conditioning/ventilation etc.

Presence mode : automatic on/off switching upon detection

Absence mode : manual switching on with push button, automatic switching off

Factory pre-set : time delay 15 minutes, light level threshold 500 lux for false ceiling sensors, 300 lux for flush mounted sensors

Precise adjustment through mobile configurators

Pack

Cat. Nos.

RJ 45-BUS/SCS connector

Allows controller(s) and sensor(s) to be connected

directly using BUS/SCS wiring by branch connection

1

0488 72 Male connector

RJ 45 doubler

10

0488 68 Allows the number of controller inputs to be doubled

Mobile configurators

All sensors are pre-set in the factory

- lighting threshold : 500 lux in false ceiling, 300 lux

surface mounted

- time delay : 15 minutes and walkthrough function

activated

Mobile configurators allow the pre-adjusted

settings and the detection sensitivity to be

readjusted

1

0882 35 Step by step programming via pre-set buttons

1

0882 30 Digital programming to the nearest decimal place

Instant programming control

Allows the settings of each sensor to be displayed

Option of putting adjustment settings in the memory

and using them for other sensors

IR remote control - ON/OFF-dimming control

1

0882 31 Allows to manage 2 directions and general switch off

Powered by two 1. 5 V LR 03 alkaline batteries

(supplied)

For remote control of sensors Cat. Nos.

0488 05/06/07/08/09/10/13/20/21/22/23/24/25

(see opposite)

Surface mounting boxes

Used for surface mounting ceiling sensors

5

0488 74 For false ceiling sensors Cat. Nos. 0488 03 (see

p.80), 0488 07 (see p.81) and 0488 20 (see

opposite)

5

0488 75 For false ceiling sensors Cat. Nos. 0488 05/06,

0488 17 (see p.81), 0488 21/22 (see opposite) and

0488 35 (see p.99)

0488 68

0488 72

0488 23 (see opposite)

0882 30

0882 35

+

Main characteristics and applications selection charts p. 78-79 Technical characteristics p. 84-85

lighting management

standalone sensors - 2 outputs (continued)

for areas benefitting from natural light

NEW

NEW

83

NEW