Background Image
Table of Contents Table of Contents
Previous Page  90 / 244 Next Page
Information
Show Menu
Previous Page 90 / 244 Next Page
Page Background

Pack

Cat. Nos.

360° ceiling sensors (indoor)

Fixed directly to a false ceiling with mounting claws

(supplied) or installed in 50 mm deep flush mounting

box or in surface mounting box Cat. Nos. 0488 74/75,

see opposite

Connect to 2 circuit controller Cat. No. 0488 50,

see opposite, by cord or RJ 45 cable or BUS/SCS

cable fitted with RJ 45 connector Cat. No. 0488 72,

see opposite

Detection field 45 m² - for private offices

PIR - Ø8 m - IP 20

Optimum distance between 2 sensors : 6 m

Consumption 0 . 2 W on standby

1

0488 20 RJ 45 connection

All loads 10 A - 240 V

Detection field 90 m² - for meeting rooms or

large offices

Dual-tech - Ø11 m - IP 20

Optimum distance between 2 sensors : 10 m

Consumption 0 . 5 W on standby

1

0488 22 RJ 45 connection

All loads 10 A - 240 V

Detection field 45 m² - for enclosed spaces with

obstacles

Ultrasonic - Ø8 m - IP 20

Optimum distance between 2 sensors : 6 m

Consumption 0 . 5 W on standby

1

0488 21 RJ 45 connection

All loads 10 A - 240 V

0488 22

0488 20

0488 50 (see opposite)

0488 50 (see opposite)

Automatic lighting management in areas that benefit from natural light : e.g. individual and open-plan offices, meeting rooms + Management of an

additional circuit - lighting/air conditioning/ventilation etc.

Presence mode : automatic on/off switching upon detection

Absence mode : manual switching on with push button, automatic switching off

Factory pre-set : time delay 15 minutes, light level threshold 500 lux for false ceiling sensors, 300 lux for flush mounted sensors

Precise adjustment through mobile configurators

Pack

Cat. Nos.

Wall sensors

Supplied with fixing base

Connect to 2 circuit controller Cat. No. 0488 50,

see opposite, by cord or RJ 45 cable or BUS/SCS

cable fitted with RJ 45 connector Cat. No. 0488 72,

see opposite

180° corner sensor (indoor) - Detection field 45 m² -

for small of f ices

PIR - Maximum range 8 m - IP 42

Optimum distance between 2 sensors : 6 m

Consumption 0 . 2 W on standby

1

0488 24 RJ 45 connection

All loads 10 A - 240 V

180° corner sensor (indoor) - Detection field 90 m² -

for conference rooms and large offices

Dual-tech - Maximum range 11 m - IP 42

With directional head

Optimum distance between 2 sensors : 10 m

Consumption 0 . 2 W on standby

1

0488 23 RJ 45 connection

All loads 10 A - 240 V

270° corner sensor (outdoor) - Detection field

180 m² - for building entrances, car parks

PIR - Maximum range 15 m - IP 55

Front detection 10 m

Lateral detection 30 m (2 x 15)

Consumption 0 . 5 W on standby

1

0488 30 RJ 45 connection

All loads 10 A - 240 V

Special for corridors or very long areas -

Detection field 30 m

PIR - Front range 30 m - IP 42

With directional head

1

0488 25 Specially adapted for long narrow areas

Example : corridors, very high ceiling areas or

warehouses

+

+

Main characteristics and applications selection charts p. 78-79 Technical characteristics p. 84-85

lighting management

standalone sensors - 2 outputs

for areas benefitting from natural light

82