Automatic lighting management in infrequently used areas : e.g. garages, storage spaces, corridors...

Mode : automatic on/off switching upon detection

Manual adjustment of light level threshold and time delay via thumbwheel/screwdriver

Pack

Cat. Nos.

360° ceiling sensor (indoor) -

Detection field 45 m²

Fixed directly to a false ceiling with mounting claws

(supplied) or installed in 50 mm deep flush mounting

box or in surface mounting box Cat. Nos. 0488

74/75, see p. 83

PIR - Ø8 m - IP 20

Optimum distance between 2 sensors : 6 m

Consumption 0 . 4 W on standby

1

0488 03 Automatic terminal connection

All loads 8 . 5 A - 240 V

180° wall sensor (indoor) -

Detection field 45 m²

Supplied with fixing base

PIR - Maximum range 8 m - IP 20

Optimum distance between 2 sensors : 6 m

Consumption 0 . 4 W on standby

1

0488 11 Automatic terminal connection

All loads 8 . 5 A - 240 V

Pack

Cat. Nos.

360° wall sensors (outdoor) -

Detection field 45 m²

PIR - Maximum range 8 m - IP 55

Coverage pattern adjustable during installation process

Screw terminal connection

1

0697 40 Grey

1

0697 80 White

180° switch sensors (indoor) -

Detection field 15 m²

Wall mounting

PIR - Maximum range 8 m - IP 41

Screw terminal connection

Arteor

1

5740 47 White - With neutral

1

5740 97 Magnesium - With neutral

1

5740 34 White - Without neutral

1

5740 94 Magnesium - Without neutral

0488 03

0697 80

0488 11

5740 47

Main characteristics and applications selection charts p. 78-79 Technical characteristics p. 84-85