lighting management

BUS/SCS and BUS/KNX sensors

BUS sensor for automatic lighting management in areas that benefit from natural light : (e.g. individual and open-plan offices, meeting rooms)

To combine with BUS/SCS system (p. 88 to 93) or BUS/KNX system (p. 94 to 97)

Presence mode : automatic on/off switching upon detection

Absence mode : manual switching on with push button, automatic switching off

Factory pre-set : time delay 15 minutes, light level threshold 500 lux for false ceiling sensors, 300 lux for flush mounted sensors

Precise adjustment through mobile configurators

0488 20

0488 22

0488 24

Pack

Cat. Nos.

360° ceiling sensors (indoor)

Fixed directly to a false ceiling with mounting claws

(supplied) or installed in 50 mm deep flush mounting

box or in surface mounting box Cat. Nos. 0488 74/75

Connect to SCS or KNX controllers with connector

Cat. No. 0488 72 - IP 20

Detection field 45 m² - for private offices

PIR - Ø8 m - IP 20

Optimum distance between 2 sensors : 6 m

Consumption 0 . 2 W on standby

1

0488 20 RJ 45 connection

All loads 10 A - 240 V

Detection field 90 m² - for meeting rooms or large

offices

Dual-tech - Ø11 m - IP 20

Optimum distance between 2 sensors : 10 m

Consumption 0 . 5 W on standby

1

0488 22 RJ 45 connection

All loads 10 A - 240 V

Detection field 45 m² - for enclosed spaces with

obstacles

Ultrasonic - Ø14 m IP 20

Optimum distance between 2 sensors : 12 m

Consumption 0 . 5 W on standby

1

0488 21 RJ 45 connection

All loads 10 A - 240 V

180° and 270° wall sensors

Supplied with fixing base

Connect to 2 circuit controller Cat. No. 0488 50,

see p. 83, by cord or RJ 45 cable or BUS/SCS cable

fitted with RJ 45 connector Cat. No. 0488 72

180° corner sensor (indoor) - Detection field

45 m² - for small offices

PIR - Maximum range 8 m - IP 42

Optimum distance between 2 sensors : 6 m

Consumption 0 . 2 W on standby

1

0488 24 RJ 45 connection

All loads 10 A - 240 V

180° corner sensor (indoor) - Detection field

90 m² - for conference rooms and large offices

Dual-tech - Maximum range 11 m - IP 42

With directional head

Optimum distance between 2 sensors : 10 m

Consumption 0 . 2 W on standby

1

0488 23 RJ 45 connection

All loads 10 A - 240 V

270° corner sensor (outdoor) - Detection field

180 m² - for building entrances, car parks

PIR - Maximum range 15 m - IP 55

Front detection 10 m

Lateral detection 30 m (2 x 15)

Consumption 0 . 5 W on standby

1

0488 30 RJ 45 connection

All loads 10 A - 240 V

Pack

Cat. Nos.

Special for corridors or very long areas

PIR front range 30 m - IP 42

With directional head

1

0488 25 Specially adapted for long narrow areas

Example : corridors, very high ceiling areas or

warehouses

180° switch sensors -

Detection field 15 m²

Presence sensors

Arteor

PIR -Maximum range 10 m - IP 41

1

5740 46 White

1

5740 96 Magnesium

Absence sensors

Arteor

Dual-tech - Maximum range 10 m - IP 41

1

5740 48 White

1

5740 98 Magnesium

Lighting measurement cell

1

0488 28 Used in conjunction with detectors, it allows

synchronisation of lighting measurement

Mobile configurator must be used to configure the

lighting cell Cat. No. 0882 30, see p. 93

Connects to BUS/SCS cable with connector

Cat. No. 0488 72

RJ 45-BUS/SCS connectors

Allow controller(s) and detector(s) to be connected

directly using BUS/SCS wiring by branch connection

1

0488 72 Male connector

1

0488 73 Female connector

Surface mounting boxes

Used for surface mounting ceiling sensors

5

0488 74 For ceiling sensors Cat. Nos. 0488 03, 0488 07

and 0488 20

5

0488 75 For ceiling sensors Cat. Nos. 0488 05/06, 0488 17,

0488 21/22 and 0488 35

How to select your system p. 89

87

NEW

Selection charts p. 86 + 90-91