685

FLOOR SYSTEMS

SCREEDED

For a full range of corresponding products,

see pages 403-411 in the product selector.

Onix Plus™ Technical

Onix Plus

Floorboxes

100 MIN.

55

85 MIN.

SCREED DEPTH

FINISHED FLOOR

* The Snorkel cord outlet cannot be used in depths less

than 100mm.

C

A

D

A

D

E

B

A

B

CENTRE CORD OUTLET

EDGE CORD OUTLET

BLANK LID

Lid Recess Dimensions

The dimensions in the table provide the sizes for the floor covering insert for the lid.

DIMENSION (mm)

BOX SIZE

A

B

C

D

E

200x200mm 183

183

102

31

45

265x265mm 248

248

102

63

45

340x340mm 323

323

102

101

45

Note:

Due to the weight of the lid and floor covering, a tile lifter, not the cord outlets, should be

used to lift these lids.

Screed Depth Table – for Snorkel Lid with Flush Accessories

WIRING SPACE

(mm)

FLOOR TILE THICKNESS

– INCLUDING ADHESIVE

(mm)

MINIMUM SCREED

DEPTH (mm)

MINIMUM

FINISHED FLOOR

DEPTH (mm)

25

15

85

100

25

20

80

100

25

25

75

100

25

30

70

100

35

15

95

110

35

20

90

110

35

25

85

110

35

30

80

110

45

15

105

120

45

20

105

120

45

25

95

120

45

30

90

120

l

Decide Wiring Space required: 25mm, 35mm or 45mm

l

Decided Floor Tile Thickness. (This must align with the lid depth choice)

l

Read across to determine the minimum screed depth and subsequent finish floor

thickness

Note:

When using the wave plate (CXP20215 / CXPC20215) or ST fibre plate (CXP20500 /

CXPC20500) the minimum screed depth and minimum finished floor depth must be increased

by 15mm. This will result in restrictions when utilising a 45mm wiring space.

Standards and Approvals

These products are designed to withstand

heavier than normal traffic loading as found in

office buildings. The Onix Plus

range supports

compliance with the requirements of the

17th Edition of the IET Wiring Regulations

(BS 7671) and to BS EN 50085 Part 1 and EN

50085-2-2. Additionally the floorboxes also

comply with IEC 60670 Parts 1 and 23.

TECHNICAL SPECIFICATION

MATERIALS

BOX LID AND FRAMES

Lid, load plate and frame manufactured in stainless

steel. Cord Outlet mouldings are manufactured from a

UL94 V2 rated nylon.

POWER GROMMET

Service outlet is die cast aluminium, brass or nickel

plated brass. The base unit is pre-galvanised steel.

Plastic parts are polycarbonate.

RAL COLOURS

Grey (GRY) = RAL 7011

Beige (BEG) = RAL 1019

FEATURE BENEFITS

l

Wet washable and IP44 when not in use

l

Tested to EN 50085-2-2 to accept 10,000N load

(5,000N load for Onix Plus Grommet)

l

Selection of lid recess depths available,

allowing for various floor depths

l

Designed to support Cat 6 structured cabling

systems

l

Wide range of power and data accessories

available to meet all requirements

l

Quality, reliability and safety come as standard

l

Provision of RCD protection supports compliance

with the 17th Edition of the IET Wiring

Regulations (BS 7671)

l

5 year guarantee

Wet Wash Test

The plain lid and the centre Snorkel outlet

lids have an Ingress Protection rating of IP44,

according to BS EN 60529:1992

Centre Cord Outlet Restrictions

This applies to the Snorkel Cord Outlet lid.