Total Solution to Earthing & Lightning Protection |
9AKK106354A3360
11
Mains power protection
ESP 5A/BX & 16A/BX Series
Combined Type 2 and 3 tested protector (to BS EN 61643) for use on low
current (up to 5 or 16 A) single phase systems to protect connected electronic
equipment from transient overvoltages on the mains supply, e.g. fire/intruder
alarm panels. Protectors with /BX suffix come ready-boxed, to IP66, for use in
dirty or damp environments. Available for 90-150 Volts, 200-280 Volts and
232-350 Volts supplies. For use at boundaries LPZ 1 through to LPZ 3 to protect
sensitive electronic equipment.
Accessories
If several
ESP 120-5A
or 16A,
ESP
240-5A
or 16A or
ESP 277-5A
or 16A
protectors are to be installed together,
or if one is in use alongside Lightning
Barriers for video or signal lines, these
can be simultaneously mounted and
earthed on a CME kit and housed in a
suitable WBX enclosure.
Full product range order codes can
be found on pages 17/8-17/9
NOTE:
If your supply is fused at more than 16 Amps the ESP 120 M1, ESP 240 M1 or ESP 277 M1 are suitable.
Connect in-line on supplies fused up to 5 A
(ESP 120-5A/BX, ESP 240-5A/BX or ESP 277-5A/BX)
or 16 A (ESP 120-16A/BX, ESP 240-16A/BX
or ESP 277-16A/BX). Note how the protector can
also be earthed from its earth stud
Connect in-line on supplies fused up to 5 A
(ESP 120-5A, ESP 240-5A or ESP 277-5A)
or 16 A (ESP 120-16A, ESP 240-16A or ESP
277-16A). Note how the protector can also
be earthed from its earth stud
47-63Hz
DIRTY
CLEAN
To
equipment
From line
DIRTY
CLEAN
To
equipment
From
line
Earth
Earth
Features & benefits
–– Very low let-through voltage (enhanced protection to
IEC/BS EN 62305) between all sets of conductors (phase
to neutral, phase to earth, neutral to earth - Full Mode
protection)
allowing continuous operation of equipment
–– Repeated protection in lightning intense environments
–– Compact size for easy incorporation in the protected
system
–– Removable DIN rail foot for simple clip-on mounting to top
hat DIN rails (unboxed versions)
–– Colour coded terminals give a quick and easy installation
check - grey for the dirty (line) end and green for the clean
end
–– Available ready-boxed to IP66 for use in dirty or damp
environments (protectors with /BX suffix)
–– Robust housing and substantial earth stud fixing holes
ready for flat mounting
–– Maintenance free
–– ESP 240-5A/BX has Network Rail Approval PA05/02896.
NRS PADS reference 087/037285
Installation
Connect in-line with the power supply usually either within the
equipment panel (or for CCTV cameras, in an enclosure close
by), or on the fused connection that supplies equipment.
To protect equipment inside a building from transients
entering on an outgoing feed (e.g. to CCTV cameras or to
site lighting) the protector should be installed as close to
where the cable leaves the building as possible.
Unless ready boxed, protectors should be installed either
within an existing cabinet/cubicle or in a separate enclosure.
Application
Use these protectors on low current mains power supplies,
e.g. CCTV cameras, alarm panels and telemetry equipment.