164

Technical

information

LexCom Performance

The active all-in-one module provides the interface

for the LexCom Performance system. The incoming

services are distributed into the cable links on

individual pairs by the dedicated features of the core

unit, such as;

n

Broadband amplifier for TV/Radio with separate

output stages

n

Data panel with true cat.6 link performance

n

Telephone line splitter with support of 2 different

lines (maximum of 4 ren per line)

The system requires LexCom Performance cable in

its use to accommodate a link length from 2 to 50

metres.

Below the cover, the links are terminated to the

unit, and turning-adjustment of each output stage is

done per link to adapt for the lengths. Also global

adjustments for Gain and Tilt of the incoming CATV

line is possible.

If more than 8 outlets are needed in an installation, 2

or more core units can be daisy chained to achieve

16, 24,..outlets capacity.

The core unit includes power supply and connection

cords for the telephone line inputs.

Core unit electrical and technical data

Power consumption

14W max

Bandwidth

47-862 MHz (CATV on all links)

Grain forward

Global = -5 / +15 dB

Tilt (equalizer)

Global = + / - 6 dB

Input level

60-77 dBµV (CATV RF input)

Return loss

-10 dB min. (CATV RF input)

Insertion loss

RF input to DATA = 4 dB

RF input to TEST = 10 dB

DATA to RF input = 4 dB

Screening attenuation

> 90 dB (class A)

Impedance input

75 Ohm (CATV RF input)

Input voltage

12 Vdc

Construction and material data

Input interface

Tele lines: 2 x RJ11

Data ports: 8 x RJ45 STP

CATV RF: F-conn. (fe-male)

Security line: RJ3 1X

Power supply: 5.5mm jack (+ on centre)

Output interface

Cable links: LSA punch down (TIA568B)

CATV test: F-conn. (fe-male)

CATV data: F-conn. (fe-male)

Standards and approvals

Application standard

EN50083-2: emission and immunity

Cabling standards

EN50173:2002 Cat.6 PL

A 4-pair high bandwidth and double shielded

installation cable for LexCom Performance

applications. It offers Superior shielding with each

pair individually shielded in metal foil and the overall

tinned copper wire braid (S/STP).

The cable is specifically matching the applications

in the LexCom Performance system, using the well

known colour coding from LAN installations.

The LexCom Performance installation cable can be

used in both surface and flush mounted installations

and shows excellent resistance to damage and

reduction of performance due to stress from the

installation work.

The cable is offered in both 120 m box and 300 m

drums, where the box is matching the average cable

need for an apartment installation.

Installation cable electrical and technical data

Attenuation

47 dB @ 600 MHz / 100 meter

Bandwidth

0 - 900 MHz

Impedance

100 Ohm nom.

NEXT

93 dB @ 100MHz

80 dB @ 300 MHz

75 dB @ 600 MHz

Signal Velocity

0.8 c

Bending radius under

installation

Min. 65 mm.

Bending radius Installed Min. 30 mm.

Temperature, Installation 0 °C to +50 °C

Temperature, Operation -20 °C to +60 °C

Construction and material data

Material

LSFROH

Weight

55 kg/km

Printing

Home installation cable 2x4xAWG23 SSTP

Caloriefic Value

0.55 MJ/m

Cable Ø

7.1 mm

Colour: conductor

White/Blue, white/orange, white/green, white/brown

Colour: sheath

White RAL 9010

Standards and approvals

Absence of halogens

ISO 60754-2

Flame Retardance

ISO 60332-1 / -3

Application standard

EN 50173-1

Cable standards

EN 50288-5-1

Application standard

ISO 11801