Table of Contents Table of Contents
Previous Page  515 / 576 Next Page
Information
Show Menu
Previous Page 515 / 576 Next Page
Page Background

515

PB502624

PB502623

PB502513

ClimaSysCC

Thermal management system

Characteristics, selectionguide

Electronic thermostats

Characteristics

Electronic thermostat

Electronic hygrotherm

Electronic hygrostat

With LED screen

With LED screen

With LED screen

Electronic temperature controller.

Electronic temperature and humidity

controller.

Electronic humidity controller.

Ingress protection rating

IP20

IP20

IP20

Certification

UL / UR

UL / UR

UL / UR

Internal sensor element

Temperature sensor

Temperature sensor and humidity sensor Humidity sensor

Contact

Free with zero potential

Free with zero potential

Free with zero potential

Connection

2 x 2.5 mm

2

(input voltage) + 2 relays

(2 x 2.5 mm

2

+ 2 x 2.5 mm

2

)

2 x 2.5 mm

2

(input voltage) + 2 relays

(2 x 2.5 mm

2

+ 2 x 2.5 mm

2

)

2 x 2.5 mm

2

(input voltage) + 1 relay

(2 x 2.5 mm

2

)

Mounting

4 different methods: by DIN rail,

Spacial SF profile, on VDI cross-rail

or on mounting plate

4 different methods: by DIN rail,

Spacial SF profile, on VDI cross-rail

or on mounting plate

4 different methods: by DIN rail,

Spacial SF profile, on VDI cross-rail

or on mounting plate

Enclosure

UL 94 V-0 plastic, light grey

UL 94 V-0 plastic, light grey

UL 94 V-0 plastic, light grey

Operating temperature

-40°C…+80°C

-40°C…+80°C

-40°C…+80°C

Hysteresis

Programmed 2°K

3 %

3 %

Temperature setting range

-40°C…+80°C

-40°C…+80°C

-

Humidity setting range

-

20 %…80 %

20 %…80 %

Display

°C or °F

°C or °F or % RH

% RH

Max. command intensity

8 (5) A 230 V AC / 5 A 30 V DC

8 (5) A 230 V AC / 5 A 30 V DC

8 (5) A 230 V AC / 5 A 30 V DC

Voltage (type of current)

References

9-30 V (AC/DC)

NSYCCOTH30VID

NSYCCOHYT30VID

NSYCCOHY30VID

110-127 V (AC)

NSYCCOTH120VID

NSYCCOHYT120VID

NSYCCOHY120VID

220-240 V (AC)

NSYCCOTH230VID

NSYCCOHYT230VID

NSYCCOHY230VID

L

N

Load1

Load2

L

N

Load (1) = fan/resistance

Load (2) = fan/resistance/alarm

Load1

Load2

S2

ºt

S1

ºt

S1A S1BS2A S2B

NO1 C1 C2 NO2

L N

S2ºt

S1ºt

L

N

Load1

Load2

NO1

C1 C2 NO2

L N

S1A S1B S2A S2B

DB300550EN-80

L

N

Load1

Load2

L

N

Load1

Load2

S1

ºt

S1A S1B

NO1 C1 C2 NO2

L N

S1ºt

L

N

Load1

Load2

NO1

C1 C2 NO2

L N

Load (1) = fan/resistance

Load (2) = fan/resistance/alarm

DB300551EN-80

L

N

Load1

Load2

L

N

Load1

Load2

NO1 C1 C2 NO2

L N

L

N

Load1

Load2

NO1

C1 C2 NO2

L N

Load (1) = fan/resistance

Load (2) = fan/resistance/alarm

DB300552EN-80

New