510

ClimaSysCR

Thermal management system

Characteristics

Insulated PTC resistance heaters

Characteristics

Material

Conditions of use

Ingress protection rating

Certifications

Power at 0°C

Voltage

Surface temperature

Electric connection

Mounting

10 W

110-250 V AC

<70°C, except for the top

protection grille

2 poles, 2.5 mm²

Quick by clip on a 35-mm

DIN rail

10 W

12-24 V DC

20 W

110-250 V AC

20 W

12-24 V DC

55 W

110-250 V AC

<70°C, except for the top

protection grille

4 poles, 2.5 mm²

By clip on a 35-mm

DIN rail

55 W

12-24 V DC

55 W

270-420 V AC

100 W

110-250 V AC

100 W

12-24 V DC

100 W

270-420 V AC

147 W

110-250 V AC

147 W

12-24 V DC

177 W

230 V AC / 50-60 HZ

Max. 50°C in the enclosure,

100°C on the top protection

grille, (for an ambient

temperature of 20°C / 68°F)

2 poles, 2.5 mm²

By clip on a 35-mm

DIN rail