Background Image
Table of Contents Table of Contents
Previous Page  25 / 36 Next Page
Information
Show Menu
Previous Page 25 / 36 Next Page
Page Background

25

Cat. Nos. 0390 71/72/73/74

Viking 3

heavy duty terminal blocks

A

B'

C

B

A min.

A max.

E

C

H

G

F

D

mm

2

35

70

95

120

150

185

300

AWG

2

00

0000

250

300

350

600

Cable section equivalence table

Characteristics of heavy duty plate terminal blocks

Separation barriers

Dimensions (mm)

IEC EN 60947-7-1

Fire resistance:

960°C, IEC EN 60695-2-11

V2 according to UL 94

Insulating material: polyamide - 30 °C

to + 100 °C

Cat. Nos. 0390 31/32/33/34

Voltage (V) Intensity (A)

Cat. Nos.

IEC

IEC

0390 31/71

1000

125

0390 32/72

1000

192

0390 33/73

1000

269

0390 34/74

1000

415

Dimensions (mm)

Dimensions (mm)

Cat. Nos.

A max. A min.

B

C

D

E

F

G

H

0390 13

227

155

36

82

73

88

176

185

191

0390 10/14/17/20

296

200

42

83 . 5

74 . 5

89 . 5

212

221

227

0390 11/15/18/21

337

216

55

107 . 3 98 . 5 113 . 5

257

266

272

B

A

Cat. Nos. A

B Thickness

0394 77

106

82 8

0394 78

188

102 12

Cat. Nos. 0394 77/78

Cat. Nos.

A

B B'

C

0390 31

M 8

56

84

0390 32

M 10 61

84

0390 33

M 10 61

84

0390 34

M 12 64

86

0390 71

M 8

55 . 3

84

0390 72

M 10

60 . 4

84

0390 73

M 10

60 . 4

84

0390 74

M 12

63 . 5

86

C

A

B

Characteristics of heavy duty terminal blocks for copper

and aluminium cables

IK 04

Conform to IEC 60947-7-1, EN 60947-7-1

UL 1059 and 486 E - CSA 22-2

Fire resistant IEC 60695-2-11: 960°C (except cover)

V2 according to UL 94

Insulation voltage Ui: 1000 V

Impulse voltage Uimp: 12 kV

Insulating material:

- polyamide body - 30 °C to + 100 °C

- polypropylene cover - 25 °C to + 100 °C

Connection table

Currents table

Terminal for cable lug - cable Cable - terminal for cable lug

Cable - cable

Terminal for cable lug -

terminal for cable lug

Cat. Nos.

Connection

Width of Screw Connection

Width of Screw Width

(mm

2

)

plate (mm)

Ø

(mm

2

)

plate (mm)

Ø

(mm)

Cable - Cable

0390 10

Rigid or flexible

Rigid or flexible

42

Cu/Al: 35 to 120

Cu: 35 to 70

0390 11

Rigid or flexible

Rigid or flexible

55

Cu/Al: 70 to 300

Cu: 70 to 150

Terminal for cable lug - Terminal for cable lug

0390 13

Cu/Al: max. 95

28

M 8 Cu/Al: max. 95

28

M 8

36

0390 14

Cu/Al: max. 150

34

M 10 Cu/Al: max. 150

34

M 10

42

0390 15

Cu/Al: max. 300

46

M 12 Cu/Al: max. 300

46

M 12

55

Terminal for cable lug - Cable

0390 17

Cu/Al: max. 150

34

M

10

Rigid or flexible

42

Cu: 35 to 95

0390 18

Cu/Al: max. 300

46

M

12

Rigid or flexible

55

Cu: 70 to 150

Cable - Terminal for cable lug

Rigid or flexible

0390 20

Cu: 35 to 120

Cu/Al: max. 120

34

M 10

42

Al: 35 to 120

Cu/Al: max. 70

34

M 10

42

Rigid or flexible

0390 21

Cu: 70 to 300

Cu/Al: max. 300

46

M 12

55

Al: 70 to 300

Cu/Al: max.150

46

M 12

55

Cat. Nos.

Current (A)

Short-circuit

Tightening torque

Width

current (kA)

(Nm)

Shunted

I/O

Shunted

I/O

Site

Factory

(mm)

input

currents

input

IEC

IEC CSA UL

Cable - Cable

0390 10

340

250 200 170

14 . 4

8 . 4

15

15

42

0390 11

570

400 300 285

36

18

35

35

55

Terminal for cable lug - Terminal for cable lug

0390 13

310

310 250 230

11 . 4

11 . 4

15

15

36

0390 14

415

415 340 285

18

18

15

15

42

0390 15

670

670 520 420

36

36

35

35

55

Terminal for cable lug - Cable

0390 17

415

315 210 230

18

11 . 4

15

15

42

0390 18

670

420 325 285

36

18

35

35

55

Cable - Terminal for cable lug

0390 20

340

340 235 255

14 . 4

8 . 4

15

15

42

0390 21

570

570 375 420

36

18

35

35

55

Shunts

0394 46

450 max.

6

0394 47

700 max.

10