Table of Contents Table of Contents
Previous Page  531 / 759 Next Page
Information
Show Menu
Previous Page 531 / 759 Next Page
Page Background

Technical Hotline

+44 (0)1268 563720

531

Grid Plus Dimmer Switches

57

59

25

57

59

49

Dimensions

Do not connect more than the maximum number of transformers stated for each

dimmer. Grid Plus dimmer switch ratings are for each dimmer when installed singly.

In multiple installations, each dimmer switch must be de-rated – see Table 1 above.

N

L

L

1

L

2

C

Two-way switching

(only one dimmer can be used)

L

1

L

2

C

Load

DIMMER

Supply 230V a.c. - 50Hz

2 way switch

L

N

One-way switching

L

1

L

2

C

Load

DIMMER

Supply 230V a.c. - 50Hz

Wires must be connected to the correct dimmer terminals.

DO NOT connect earth to dimmer.

L

N

Fluorescent dimmer

1

2

HF Fluorescent

Ballast

3

+

Wires must be connected to the correct dimmer terminals.

DO NOT connect earth to dimmer.

1-10V

DIMMING

CONTROLLER

Wiring Diagrams

TABLE 2 – OVERLOAD REACTION

40-400W CIRCUIT

40-300W CIRCUIT

COMMENTS

Overload management

Overload management

This is the

minimum

controlled voltage

40-400W nominal

40-220W nominal

40-500W function without dimming

40-275W function without dimming

> 500-700W dim to 68V±8V r.m.s.

> 275-375W dim to 68V±8V r.m.s.

> 700W switch off

> 375W switch off

1 gang

2 gang

TABLE 3 – GRID PLUS INTELLIGENT DIMMER SWITCHES

RATING

MAX NO. OF

TRANSFORMERS

1 module dimmer switch

40-220W (LV rating 40-180VA)

3

2 module dimmer switch

40-400W (LV rating 40-320VA)

5

TABLE 1 – LOAD ADJUSTMENT FOR GRID PLUS DIMMERS

FRONTPLATE SIZE, NUMBER OF GANGS

2

3

4

6

8

9

12

18

24

Max Power/Load per Row – Tungsten GLS Lamps – W

400

480

480

480

480

480

480

720

720

Max Power/Load per Row – Mains Tungsten Halogen

Lamps or Low Voltage Transformers – W or VA

320

380

380

380

380

380

380

580

580

Max Power/Load for Total Plate – Tungsten GLS Lamps – W 400

480

480

740

740

940

940

1440

1800

Max Power/Load for Total Plate – Mains Tungsten Halogen

Lamps or Low Voltage Transformers – W or VA

320

380

380

600

600

750

750

1155

1440

K4511 – No derating is required for LED load types.

Fluorescent Dimmer

MK Fluorescent dimmers are low voltage

controllers that require only a single two-core wire

connection to 1-10V controllable ballast inputs.

The dimmer operates by applying a variable

resistance to the ballast 1-10V control input.

We recommend using a separate on/off switch

to isolate the luminaire(s) in use.

Features

Preset adjust to set minimum light level. Preset

adjust for use with multiple dimmable ballasts.

Up to four ballasts can be connected to one

dimmer.

Grid Plus Technical

WIRING DEVICES

MODULAR