Table of Contents Table of Contents
Previous Page  215 / 221 Next Page
Information
Show Menu
Previous Page 215 / 221 Next Page
Page Background

208

INGRESS PROTECTION (IP) RATING ACCORDING TO EN 60529 - CEI 70-1

1st CHARACTERISTIC NUMBER:

PROTECTION AGAINST INGRESS OF SOLID MATTER

Protection against

ingress of solid

matter caused by

Test method

Accessibility gauge

ø 50 mm

Accessibility gauge

ø 12,5 mm

Accessibility gauge

ø 2,5 mm

Accessibility gauge

ø 1 mm

talcum

powder

talcum

powder

solid bodies

measuring

over 12,5 mm

solid bodies

measuring

over 2,5 mm

solid bodies

measuring

over 1 mm

powder in

harmful quantities

Powder

(completely protected )

0

1

PROTECTION

2

3

4

5

6

2nd CHARACTERISTIC NUMBER:

PROTECTION AGAINST INGRESS OF LIQUIDS

1st ADDITIONAL LETTER

RESTRICTED ENTRY TO DANGEROUS PARTS

Protection

against ingress of

liquids caused by

Test method

Permanent

Immersion

PROTECTION

8

Temporary

Immersion

7

Powerful jets of

water

6

Jets of water

5

Sprays of water

4

Rain

3

Vertical drops of

water with

inclination

of casing up to 15°

2

Drops of water

falling vertically

1 0

Agreement between

manufacturer and

user but more

severe than 7

solid bodies

measuring

over 50 mm

A

RESTRICTED

ENTRY

B

C

D

Test method

accessibility gauge

ø 50 mm

articulated test finger

accessibility gauge

ø 2,5 mm

Restricted entry to

dangerous parts

caused by

back of hand

finger

tool

wire

2nd ADDITIONAL LETTER

MEANING OF THE SECOND ADDITIONAL LETTER

H

SPECIFIC

CRITERIA

M

S

W

Specific criteria

High voltage equipment

Tested against negative effects of water

penetration, when the moveable parts

of the equipment (e.g. wheels

of a revolving machine) are moving

Tested against the negative effects of water

penetration, when the moveable parts

of the equipment (e.g. wheels

of a revolving machine) are stationary

Suitable for use in environmental

conditions as specified and equipped

with additional measures

of protection

The first digit (0-6 or X letter):

Protection against ingress of solid matter

Second digit (0-8 or X letter):

Protection against ingress of liquids

(A, B, C, D) for future use.

Restricted entry to dangerous parts:

(H,M,S,W) for future use. Specific criteria:

accessibility gauge

ø 1 mm