Total Solution to Earthing & Lightning Protection |

9AKK106354A3360

12

Combined Category D, C, B tested protector (to BS EN 61643) suitable for use

on ten line LSA-PLUS disconnection modules to protect individual twisted

pair data or signal lines. For use at boundaries up to LPZ

0

to protect against

flashover (typically the service entrance location) through to LPZ 3 to protect

sensitive electronic equipment.

Data & signal protection

ESP KS & KE Series

Installation

Install protectors on all data communication and signal

lines that enter or leave each building. All protectors must

be installed via the ESP KE10 earth bar. Identify the lines

requiring protection and clip the ESP KE10 on to the

disconnection modules’ earth points. Plug the protector

directly into each disconnection module requiring protection

(ensuring the correct orientation) for a series connection.

In the unlikely situation that the protector is damaged, it

will sacrifice itself and fail short circuit, taking the line out of

commission. In addition to indicating that the protector needs

replacing, this will also prevent subsequent transients from

damaging the equipment.

NOTE:

For PSTN and U interface ISDN lines on LSA-PLUS modules, use the ESP KT1 or ESP K10T1. For S/T interface ISDN lines on LSA-PLUS modules, use

the ESP KT2 or ESP K10T2. For individual twisted pair data or signal lines, use the ESP D, E or H Series Lightning Barriers. The ESP SL and ESP Q Series

Lightning Barriers are suitable for high density data and signal lines.

Features & benefits

–– Low cost protection for large numbers of data and

signal lines

–– Very low let-through voltage (enhanced protection

to IEC/BS EN 62305) between all lines - Full Mode

protection

–– Full Mode design capable of handling partial lightning

currents as well as allowing continual operation of

protected equipment

–– Repeated protection in lightning intense environments

–– Quick and easy plug-in installation

–– Colour of housing distinguishes electrically different

protectors to help avoid confusion when installed with

other protectors (e.g. the ESP KT1/2) on the same

distribution frame

–– Protect only the lines you need

–– Ridged finger holds make it easy to obtain a firm grip

for installation or removal

–– Use the ESP KE10 to provide trouble free earthing for up

to ten protectors (per disconnection module)

Application

Use these units to protect signal, data, control and

instrumentation systems with LSA-PLUS

disconnection modules.

Full product range order codes can be found on pages 17/8-17/9