Table of Contents Table of Contents
Previous Page  203 / 336 Next Page
Information
Show Menu
Previous Page 203 / 336 Next Page
Page Background

Total Solution to Earthing & Lightning Protection |

9AKK106354A3360

11/3

11

Mains protectors for specific sytems

Fire/intruder alarm panels and CCTV systems

Photovoltaic (solar) panels

Mains power protection

Product selector - Service entrance to terminal equipment

Ground

Level

LPS

Power

Unknown

Ground

Level

Power

Ground

Level

LPS

Power

Data

Telecom

Water

Gas

No external lightning protection system LPS fitted,

3 Phase 415V TN-S or TN-C-S mains supply -

exposed overhead supply feed

External lightning protection system LPS fitted,

multiple connected metallic services (gas/water/

data/telecom) 3 Phase 415V TN-S or TN-C-S mains

supply

External lightning protection system LPS fitted,

metallic gas/water/ data/telecom services -unknown

3 Phase 415V TN-S or TN-C-S mains supply

Installation Locations

Service entrance - after meter

Sub Distribution Board (SDB) - Critical terminal equipment -

Sturcture configuration - typical

Main Distribution Board (MDB)

located > 10m from MDB

located > 10 m from SDB

No external lightning protection system LPS fitted,

3 Phase 415V TN-S or TN-C-S mains supply -

underground supply feed

ESP 415 D1 Series

or

ESP 415 M1 Series

For 3 Phase 415V supplies

See pages 11/10 and 11/14

ESP 415 D1 Series

For 3 Phase 415V supplies.

See page 11/10.

ESP MC Series

Hospital/Laboratory/Server

equipment. See page 11/26.

ESP MC/TN/RJ11 Series

Fax machines/Modems

See page 11/26.

ESP MC/Cat-5e Series

Computer network hubs

See page 11/26.

ESP 415 M1 Series

For 3 Phase 415V supplies.

See page 11/14.

ESP In line mains

up to 32 Amps.

See pages 11/22 & 11/24

Fire/Intruder alarm panels

See page 11/20

ESP 240 D1 Series

For single phase 240V

supplies. See page 11/6.

ESP 240 M1 Series

For single phase 240V

supplies. See page 11/14.

ESP 415 D1 Series

or For 3 Phase 415V

supplies

ESP 415 M1 Series

See pages 11/10 and 11/14

ESP 415/III/TNS Series

or where electronics

are located near MDB before SDB use

ESP 415 M2 Series

See pages 11/6 and 11/12

ESP 415/I/TNS Series

for LPS to LPL level I and II

ESP 415/III/TNS Series

for LPS to LPL level III

and IV or where electronics

are located near MDB

before SDB use

ESP 415 M2 Series

for

LPS to LPL level III & IV

are located near MDB

before SDB

ESP 415 M4 Series

for

LPS to LPL level I & II are

located near MDB

Ground

Level

Power

ESP PV Series

Photovoltaic

(solar) panels

See page 14/8.

See pages 11/4 and 11/12