Characteristics table

Magnum characteristics,

dimensions and weights

Magnum frame

Narrow frame

Standard frame

Double-wide frame

(

MWN)

(

MWI)

(

MWI)

Circuit breaker characteristics

1) 2)

4

5

6

6

6

8

C

64

84

5

800

800

800

800

~

800

800

4000

4000

4000

1000

1000

1000

1000

~

1000

1000

5000

5000

Continuous current rating I

n

1250

1250

1250

1250

~

1250

1250

6300

6300

(

Amps at 40 °C)

~

1600

1600

1600

~

1600

1600

~

2000

2000

~

2000

2000

2000

~

2500

2500

2500

~

3200

3200

3200

Interrupt ratings at 690 Vac I

cu

/

I

cs

(

kA

rms

)

40/40 50/50 65/65

65/65 65/65 85/85 100/85

4)

65/65 85/85 100/100

Withstand rating I

cw

1

sec/3 sec (kA

rms

)

40/

~ 50/~

3)

65/40

65/

~ 65/50 85/65 85/65

65/

~ 85/~ 100/~

Maximum break time (msec)

30

30

30

30

30

30

30

40

40

40

Maximum closing time (msec)

50

50

50

50

50

50

50

70

70

70

Circuit breaker dimensions (mm)

5)

Height

425.7 425.7 425.7

425.7 425.7 425.7 425.7

425.7 425.7 425.7

Fixed

Depth

371.9 371.9 371.9

371.9 371.9 371.9 371.9

371.9 371.9 371.9

Width (3-pole)

317.7 317.7 317.7

410.2 410.2 410.2 410.2

886.5 886.5 886.5

Width (4-pole)

413

413

413

537.2 537.2 537.2 537.2

1120

1120

1120

Height

524.3 524.3 524.3

524.3 524.3 524.3 524.3

524.3 524.3 524.3

Drawout

Depth

474.2 474.2 474.2

474.2 474.2 474.2 474.2

474.2 474.2 474.2

Width (3-pole)

336

336

336

431.8 431.8 431.8 431.8

909

909

909

Width (4-pole)

431.3 431.3 431.3

558.8 558.8 558.8 558.8

1036

1036

1036

Circuit breaker weight (kg)

5)

Fixed

(3-

pole)

43

43

43

58-68 58-68 58-68 58-68

107.5 125.2 125.2

(4-

pole)

54

54

54

72-86 72-86 72-86 72-86

144.7 163.3 163.3

Drawout

(3-

pole)

48

48

48

70-86 70-86 70-86 70-86

138.8 157.4 157.4

(4-

pole)

62

62

62

88-112 88-112 88-112 88-112

166

200

200

Cassette

(3-

pole)

28

28

28

53-56 53-56 53-56 53-56

90.3

96.2

96.2

(4-

pole)

32

32

32

55-68 55-68 55-68 55-68

113.4 120.7 120.7

Non-auto switch characteristics

Maximum interrupt ratings

at 690 Vac I

cu

/

I

cs

(

kA

rms

)

40/40 50/50 65/65

65/65 65/65 85/85

7)

65/65 85/85 100/100

Withstand ratings I

cw

1

sec/3 sec (kA

rms

)

40/

~ 50/~

3)

65/40

65/

~ 65/50 85/65

7)

65/

~ 85/~ 100/~

Continuous current range (A)

to 1250 to 2000 to 2000

to 1600 2000

to 2000 ~

to 4000 to 4000 to 4000

Close and latch current (kA peak)

6)

43

55

69

55

55

69

~

138

138

138

Maximum continuous current range (A)

~

~

~

~

2500 & 2500 &

~

~

5000 & 5000 &

3200

3200

6000

6000

Close and latch current (kA peak)

6)

~

~

~

~

110

110

~

~

217

217

1)

Circuit breakers equipped with integral trip units have a making current release set to trip instantaneously at 25 x I

n

peak current to prevent closing

on a fault current exceeding that magnitude.

2)

Magnum ACB’s carry an IT rating at 440 Vac per IEC 60947-2 Annex H. Contact Eaton for 690 Vac IT applications.

3)

The I

cw

1

sec/3 sec rating is 50/30 kA for 2000 A MWN 50 kA breaker.

4)

Standard frame circuit breakers rated 100 kA are equipped with a high instantaneous trip set to protect above 85 kA

rms

.

I

cu

is 100 kA and I

cs

is 85 kA at 440 Vac.

I

cu

and I

cs

are 85 kA at 690 Vac.

5)

The approximate weights and dimensions shown are based on horizontal terminals.

6)

Close and latch ratings are applicable only to non-automatic switches. Non-automatic switches should be applied with a suitable external overcurrent device with

instantaneous trip to protect above the published close and latch rating.

7)

The maximum available instantaneous interrupting rating for the standard frame non-automatic switch is 85 kA.