Background Image
Table of Contents Table of Contents
Previous Page  5 / 12 Next Page
Information
Show Menu
Previous Page 5 / 12 Next Page
Page Background

5

Three structure widths offer greater capacity

in less space

The Magnum has been engineered to fit into three

space-saving structure widths for 3-pole and three more

for 4-pole units. The Magnum breaker provides

opportunities for more circuit breakers in less space.

Reduced space means greater cost savings regarding

assembly time, number of assembly structures, and final

installation area.

Through-the-door design ensures user-friendly

operation, visual indication, and optimum safety

Through-the-door design provides clear visual and

physical access to the trip unit and ALL breaker controls

and indicators … including open and close buttons, the

open/close indicating flag, the charging handle, breaker

interlock, and the spring charge/discharge flag. Even

breaker levering is accomplished with the breaker

compartment door closed.

For safety and security, the breaker compartment allows

three breaker positions with the door closed: connect,

test, and disconnect.

Extension rails can be padlocked to prevent a breaker

from being inserted into a cell, a lock-out requirement

when maintenance is being performed. This helps

assure personnel safety and guarantees that no one can

install a breaker and energise a circuit on which a

person may be working.

Through-the-window accessories

Shunt trip

-

Provides remote controlled circuit breaker

opening when energised by a voltage input.

Spring release

-

Remotely closes the breaker when its

coil is energised by a voltage input.

Undervoltage release (UVR)

-

Trips the breaker remotely

when an existing voltage signal is lost or drops below

an established threshold.

Internal Accessories

Auxiliary switch

-

Provides the capability to remotely

indicate if the breaker is open or closed. Up to six N/O

and six N/C auxiliary contacts are available for

customer use.

Overcurrent trip switch (bell alarm)

-

A set of N/O and N/C

contacts that indicate when a breaker trips.

Electrical operator

-

An electric motor, internally mounted

in the circuit breaker, that charges the closing springs

automatically, facilitating remote or local closing.

The right choice for low voltage assemblies … anywhere in the world

In the withdrawn position, the

breaker can be removed from

the cell on integral extension

rails.

Finger-proof (IP20)

secondary points with easy

access for customer wiring.

All breakers can be padlocked

to secure the breaker in all

three positions. An optional

key interlock (not shown) can

also secure the breaker in

each position.

The drawout breaker can be

conveniently racked in or out,

stopping at the various

positions with the door closed.

The breaker spring charging

handle is designed with

sufficient space for operation

even with a gloved hand.