Background Image
Table of Contents Table of Contents
Previous Page  3 / 12 Next Page
Information
Show Menu
Previous Page 3 / 12 Next Page
Page Background

3

High withstand ratings

Magnum provides high interruption and withstand

ratings in a small physical size.

Through-the-door design

All controls, indicators, and the trip unit are visible and

can be safely accessed without opening the

compartment door.

Common height and depth

All three Magnum frame sizes have the same identical

height and depth to facilitate standardised designs in

low voltage assemblies.

Complete trip unit family

A full range of Digitrip® programmable and electronic

trip units has been expanded to offer customers a

choice of protection, information, and communication

capabilities to meet specific requirements.

Eaton’s innovations meet the needs of today’s modern

air circuit breakers:

The capability to design more flexible systems that

can withstand larger available fault currents.

Better coordination with downstream devices.

Reduced size of the switchgear assembly.

Integrally designed breaker levering mechanism and

cassette for drawout breaker with clear indication of

connect, test, and disconnect positions.

Meeting the challenge

Magnum breakers are engineered specifically for use in

low voltage assemblies applied at nominal voltages of

380, 415, 440, 500

and 690 Vac. Ten continuous ratings

– 800

A through 6300 A – are covered with three frame

sizes. Drawout and fixed mounting units are available

in 3 or 4 pole designs.

Controls and indicators are conveniently grouped on

the breaker’s front escutcheon where they can be

easily viewed and accessed through a cutout door.

High withstand ratings … in a compact size

Rear view of integrally-designed

cassette showing generous spacing

for customer bus connections.

The independently operated and

lockable shutter design provides a

safe environment when the breaker

is removed from the cassette.

Integral arc hood.

Front mounted secondary

contacts.

Trip flag (optional).

Three accessory windows.

Spring status indicator

(

charged or discharged).

5

4

3

2

1

Contact status indicator

(

open or closed).

Digitrip RMS trip unit.

Push On” to close breaker button.

Push Off” to open breaker button.

Manual charging handle.

Drawout cassette.

11

10

9

8

7

6

Optional operations counter.

Optional “Off” key lock.

Integral padlockable levering

device.

Colour-coded breaker position

indicators.

15

14

13

12

1

2

3

4

5

8

6

9

7

10

11