Additional information

The energy management

with Prisma P

Presentation

111214

+24VDC

CMD

SDOF0V

NP

OF

0VI1I2Q24V

0VI1I2Q24V

0VI1I2Q24V

0VI1I2Q24V

0VI1I2Q24V

0VI1I2Q24V

0VI1I2Q24V

0VAI1AI224V

1

2

3

4

5

6

7

8

1

2

3

4

5

6

8

+24V0V

COM

STATUS

LK/10-100/ACT

ETHERNET

NETWORK

STATUS

R

COMD1D0 0V

7

Imax:63A

iEM31

ON

C/-D1N.C.

CD0N.C.

0V

D1/+

D0/-

ETH1

ETH2

ETH1

ETH2

24VDC

POWER

POWER

Com’X200

POWER

Made inGERMANY

100-230V

~

0.6A

24V 1.2A

50/60Hz

HAZARDOFELECTRICSHOCK,

EXPLOSION,ORARCFLASH

Turnoff allpowerbeforeworkingon this equipment.

Failure to follow these instructionswill result indeath

or serious injury.

DANGER

EBX200

100-230V

Modbus

Ethernet network

ULP system

Acti 9 Smartlink Ethernet

Acti9 Smartlink Ethernet collects data from Smartlink

modbus and transfers them via the Ethernet network.

Acti 9 Smartlink Modbus

Acti9 Smartlink Modbus is used to transfer data from

Acti9 devices to a PLC or monitoring system via the

communication system: Modbus serial line.

IFE Ethernet interface module

The IFE Ethernet interface for LV circuit breaker

enables an intelligent modular unit (IMU), for

example a Masterpact NT/NW or Compact NSX

circuit breaker to be connected to an Ethernet

network. Each circuit breaker has its own IFE and a

corresponding IP address.

Com’X 200 energy server

Com’X 200 energy server is a compact, plug-and-play

data logger that merges seamlessly with the Smart

Panel energy management solution. It consolidates

inputs from analog environmental sensors (e.g.

temperature), digital readers (e.g. pulsed signals

fromsmart energy or water meters, load running

hours), and energy management equipment running

over the Modbus protocol.

Designed for ease of implementation, data can be

transmitted securely via Ethernet, Wi-Fi, or GPRS to

any energy management platforms. The Com’X 200

energy server is scalable and can be easily adaptable

to accommodate future upgrades. Com’X 200 is a

perfect fit with our energy management services,

enabling visualization, tracking, and analysis of energy

data to support optimization of energy performance

and cost management.

Module interface Modbus IFM

this module required for connection to the network,

contains the Modbus address (1 to 99) declared by

the user via the two dials in front. It automatically

adapts (baud rate, parity) to the Modbus network in

which it is installed.

It is equipped with a lock-out switch to enable or

disable operations involving writing to Micrologic, i.e.

reset, counter reset, setting modifications, device

opening and closing commands, etc.

There is a built-in test function to check the

connections of the Modbus interface module with the

Micrologic and FDM121 display unit.