raised floor systems
customer services +44 (0)1745 532343
Spider
Technical
Spider
Spider – The Relocation
Step 1
l
Lift a single floor tile to reveal the Ackermann Spider hub
l
Disconnect the services from the hub and pull cables back to desk
Step 2
l
Move desk to new location
Step 3
l
Using a cable feeder, pull cables through from new location to the hub
l
Re-connect services to their original sockets no need to re-patch data
l
Replace tile over the hub
l
All this in under ten minutes
General
l
Minimum floor void 105mm
l
Jacking legs are supplied to accommodate floor depths up to 150mm
l
For deep floor voids the Spider hub can be mounted on a platform
l
Hub manufactured from galvanised steel
l
To comply with OFTEL regulations and Low Voltage Directive the
power leads are supplied in an earthed flexible metal conduit providing
electrical segregation between power and data
l
Desking units (DeskPod™) can also be supplied – see page 35 for details
Power Hub
l
Incoming supply connected via 2 x 25mm diameter knockouts
l
Incoming supply terminal capacity 25mm
2
(
only switch disconnect
models)
l
Alternative MCB ratings and types available on request
Data Hub
l
Up to 40 RJ45 data outlets
l
Large (120mm x 35mm) aperture provides entry for data and
voice cables
l
Data module can be wired off site and installed into the hub complete
l
Alternative data options available on request
Outlets
l
Up to 12 outlets can be connected to the hub
l
50
mm diameter umbilical tubing supplied on 25m long reels and cut to
length on site to suit any configuration
l
Cut out size for floor outlets
Ø
127
mm
l
Umbilicals manufactured from fire retardant grade of polyamide