Consumer
Unit Cable Kits
Accessories
K5563s
5
SPLIT-LOAD KIT
CONSISTS OF 3 CABLES
(2 NEUTRAL AND 1 LIVE) FOR
USE WHEN ASSEMBLING A
SPLIT LOAD ARRANGEMENT
K5565s
5
MULTI-INCOMER KIT
CONSISTS OF A BLUE FLEXIBLE
CABLE WITH
PRE-FITTED TERMINAL FOR
THE NEUTRAL RETURN FROM
SWITCH OR RCD TO SECOND
OR THIRD NEUTRAL BAR
K5568s
5
17TH EDITION CABLE KIT
FOR SWITCH AND TWIN RCD
ARRANGEMENT
K5567s
5
A&D CABLE KIT FOR
SWITCH PLUS TRIPLE RCD
ARRANGEMENT
K5563S
For use when assembling split-load
arrangement.
K5565S
For use when assembling a consumer
unit in a multi-incomer arrangement
with separate supply to each incomer.
These kits must be used to ensure
compliance with BS EN 60439-3
5562s
1
EXTENSION TERMINAL FOR
USE WHEN ASSEMBLING
A CONSUMER UNIT AS A
DISTRIBUTION BOARD.
ENABLES DIRECT CONNECTION
OF CABLES TO THE NEUTRAL
BAR. CONSISTS OF A 25MM2
CAPACITY TERMINAL WITH
CLAMP SCREW
K8041s
10
LOCKING DEVICE FOR USE
WHEN LOCKING A SENTRY
MCB, RCBO, RCD OR SWITCH
DISCONNECTOR IN EITHER THE
ON OR OFF POSITION
K5593s
1
BARREL LOCK AND KEY KIT
SUITABLE FOR SECURING ‘K’
SERIES SENTRY CONSUMER
UNIT LIDS.
ONLY SUITABLE FOR HYBRID
AND INSULATED CONSUMER
UNITS
5544s
5
MCB BLANK – GREY DESIGNED
TO FILL UNUSED MODULES
IN SENTRY CONSUMER UNITS
AND SMALL ENCLOSURES.
DIN-RAIL MOUNTED
K5545sMAG
10
COVER MOUNTED BLANK FOR
FILLING SPACES IN THE ‘K’
SERIES SENTRY CONSUMER
UNIT COVER, WHERE THERE
ARE UNUSED MODULES
K5511s
1
BUSBAR 11 MODULE
K5590s
1
BUSBAR 20 MODULE
KAX26s
10
BUSBAR COVER
SUITABLE FOR INSULATING
THE BUSBARS K5511S AND
K5590S 20 MODULE.
ONLY SUITABLE FOR HYBRID
AND INSULATED CONSUMER
UNITS
K5597s
5
CONSUMER UNIT LABELS
ADDITIONAL PRINTED
AND BLANK LABELS, FOR
IDENTIFYING DEVICES AND
CIRCUITS ON DUAL & TRIPLE
RCD BOARDS
K5599s
5
CONSUMER UNIT LABELS
ADDITIONAL PRINTED
AND BLANK LABELS, FOR
IDENTIFYING DEVICES AND
CIRCUITS ON SINGLE RCD
BOARDS
K5804sD1MAG
K5808sD1MAG
K5812sD1MAG
K5816sD1MAG
K5821sD1MAG
REPLACEMENT PLASTIC
FRONT COVERS
K6060SMET
1
16 WAY METAL CONSUMER
UNIT SURFACE MOUNTING KIT
K6061SMET
1
12 WAY METAL CONSUMER
UNIT STACKING KIT
K6062SMET
1
16 WAY METAL CONSUMER
UNIT STACKING KIT
K5599s
KAX26s
K5545sMAG
5562s
K5511s
K5593s
K5563s
K5565s
5544s
K8041s
K5597s
PUSH LEVER
UP TO
SWITCH ON
PUSH LEVER
UP TO
SWITCH ON
TEST BUTTON
RCBO
RCD
TEST
BUTTON
18
17
1
11
12
13
14
15
16
17
18
19
20
21
2
3
4
5
6
7
8
9
10
19
20
21
22
23
24
MAIN
SWITCH
SOCKETS
BASE-
MENT
LIGHTS
BASE-
MENT
SOCKETS
GROUND
FLOOR
SOCKETS
FIRST
FLOOR
SOCKETS
SECOND
FLOOR
SOCKETSSOCKETSKITCHEN
SOCKETS
GARAGE
SOCKETS
RING
CIRCUIT
BASE-
MENT
RING
CIRCUIT
GROUND
FLOOR
RING
CIRCUIT
FIRST
FLOOR
RING
CIRCUIT
SECOND
FLOOR
RING
CIRCUIT
KITCHEN
RING
CIRCUIT
SECURITY
ALARM
WATER
HEATER
FREEZERFRIDGECOOKERCOMPUTERSMOKE
ALARM
SMOKE
ALARM
CLEAN
EARTH
WATER
HEATER
CENTRAL
HEATING
STORAGE
HEATER
STORAGE
HEATER
SHOWERSHOWER
LIGHTS
GROUND
FLOOR
LIGHTS
FIRST
FLOOR
LIGHTS
SECOND
FLOOR
LIGHTS
OUTSIDE
LIGHTS
ADDITIONAL INFORMATION
B RCD 'TEST' Label
C Busbar Shield Warning Label
(Factory fitted)
E Additional Information Label
F Circuit ID Labels
A RESETTING INSTRUCTION LABEL
CIRCUIT
NUMBER
LIGHTSGARAGE
LIGHTS
SECURITY
ALARM
DOOR
BELL
OUT
BUILDING
RESETTING INSTRUCTIONS
If a device switches 'OFF' in the event
of a fault, take the following action:
MCB /RCBO
•Check each appliance connected to
that device and remove if faulty.
•Push the lever up, to switch on.
•Under fault detection theMCBwill trip to a
mid-"trip" position.
ResetMCB by switching "off", then "on".
ResetRCBO by switching to "on".
RCD
•Reset the lever to the off position, if necessary.
•Push the lever up, to switch on.
• If theRCD trips again, switch off
allMCB's& switch on theRCD.
•Switch eachMCB on, one at a time.
theRCDwill switch offwhen the
faulty circuit is reconnected.
If any device still switches off (or if the RCD cannot be switched
on with all MCB's switched off) then call a qualified electrician,
or for general guidance, MK Technical Services on 01268 563720.
This installation, or part of it, is
protected by a device which
automatically switches off the supply
if an earth fault develops.
Test quarterly by pressing the button
marked 'T' or 'Test'. The device
should switch off the supply and
should then be switched on to restore
the supply.
If the device does not switch off the
supply when the button is pressed,
seek expert advice.
OFF
ON
IMPORTANT
ALLMAINSWITCHES
MUSTBESWITCHED
OFFTOCOMPLETELY
DISCONNECTTHEUNIT
FROMTHESUPPLY
WARNING
DISCONNECTTHE
MAINSSUPPLY
BEFOREREMOVING
THISCOVER
WARNING
ENSUREALLTERMINAL
SCREWSAREFULLY
TIGHTENEDBEFORE
FITTINGFRONTCOVER
MKSENTRY
CONSUMERUNIT
TOBSEN60439-3
220-250V50Hz a.c.
RATEDCURRENT
MUSTNOTEXCEED
100AMAX
OFF
ON
WARNING
DISCONNECTTHE
MAINSSUPPLY
BEFOREREMOVING
THISCOVER
MKSENTRY
CONSUMERUNIT
TOBSEN60439-3
220-250V50Hz a.c.
RATEDCURRENT
MUSTNOTEXCEED
63AMAX
RCD
PROTECTED
CIRCUITS
TEST QUARTERLY
(Cut as required)
SENTRY CONSUMER UNIT - LABEL SHEET
Please leave any unused labels with the consumer
H Main Switches Warning Labels
4 module unit
8, 12, 16 & 21 module units
G Individual Circuit Labels
Fit to prominent position on or near
Consumer Unit.
MCB
On
Off
Mid-Trip
RCD
PROTECTED
CIRCUITS
TEST QUARTERLY
RCD
PROTECTED
CIRCUITS
TEST QUARTERLY
10
9
11
12
13
14
15
16
2
1
3
4
5
6
7
8
22
23
24
U1
U2
U3
RCD
TIMEDELAYED
1234567891011121314
Pantone
485
Pantone
102
Pantone
355
Pantone
Blue??
Pantone
Black
Thisproof has been printedon a low resolution colourproofer.Coloursmay vary from final print.
Liability cannotbe acceptedbyPPL for errorsor omissionsonce the proofand job specification has been approved.
Ref:
Ono:
OurRef:
Date:
Version:
Size:
MKElectrics
22852
F641
25.03.08
v.2
228.6 x320
Time
Delay
Switches
ONE MODULE
5650s
1
DELAY RANGE
1 - 7 MINUTES (APPROX)
Suitable for installation in Sentry
Consumer Units and two or four
module enclosures. Offers time
delay control for complete circuits
of either tungsten or fluorescent
lighting with any number of standard
push switches. It can also be used
to control fans in bathrooms without
a window. Delay setting can be
over-ridden by setting to ‘Perm-on’
mode, or by fitting a remote overriding
switch. Switch has a switching
capacity of 16A Resistive loads (upf)
Fluorescent lamps uncompensated
Series compensated 1300W
Parallel compensated 480W
CFLS 100W Max. Maximum of 9 units
can be connected
Incandescent lamps 2000W
Neon glow lamp load (locating lamp
for Push Switch) 50mA max
VOLTAGE RATING:
230V 50Hz
DIMENSIONS:
84 x 18 x 70mm
CABLE CAPACITY:
1 x 4mm
2
or 2 x 1.5mm
2
5650s
PUSH LEVER
UP TO
SWITCH ON
PUSH LEVER
UP TO
SWITCH ON
TEST BUTTON
RCBO
RCD
TEST
BUTTON
18
17
1
11
12
13
14
15
16
17
18
19
20
21
2
3
4
5
6
7
8
9
10
19
20
21
22
23
24
MAIN
SWITCH
SOCKETS
BASE-
MENT
LIGHTS
BASE-
MENT
SOCKETS
GROUND
FLOOR
SOCKETS
FIRST
FLOOR
SOCKETS
SECOND
FLOOR
SOCKETSSOCKETSKITCHEN
SOCKETS
GARAGE
SOCKETS
RING
CIRCUIT
BASE-
MENT
RING
CIRCUIT
GROUND
FLOOR
RING
CIRCUIT
FIRST
FLOOR
RING
CIRCUIT
SECOND
FLOOR
RING
CIRCUIT
KITCHEN
RING
CIRCUIT
SECURITY
ALARM
WATER
HEATER
FREEZERFRIDGECOOKERCOMPUTERSMOKE
ALARM
SMOKE
ALARM
CLEAN
EARTH
WATER
HEATER
CENTRAL
HEATING
STORAGE
HEATER
STORAGE
HEATER
SHOWERSHOWER
LIGHTS
GROUND
FLOOR
LIGHTS
FIRST
FLOOR
LIGHTS
SECOND
FLOOR
LIGHTS
OUTSIDE
LIGHTS
ADDITIONAL INFORMATION
B RCD 'TEST' Label
C Busbar Shield Warning Label
(Factory fitted)
E Additional Information Label
F Circuit ID Labels
A RESETTING INSTRUCTION LABEL
CIRCUIT
NUMBER
LIGHTSGARAGE
LIGHTS
SECURITY
ALARM
DOOR
BELL
OUT
BUILDING
RESETTING INSTRUCTIONS
If a device switches 'OFF' in the event
of a fault, take the following action:
MCB /RCBO
•Check each appliance connected to
that device and remove if faulty.
•Push the lever up, to switch on.
•Under fault detection theMCBwill trip to a
mid-"trip" position.
ResetMCB by switching "off", then "on".
ResetRCBO by switching to "on".
RCD
•Reset the lever to the off position, if necessary.
•Push the lever up, to switch on.
• If theRCD trips again, switch off
allMCB's& switch on theRCD.
•Switch eachMCB on, one at a time.
theRCDwill switch offwhen the
faulty circuit is reconnected.
If any device still switches off (or if the RCD cannot be switched
on with all MCB's switched off) then call a qualified electrician,
or for general guidance, MK Technical Services on 01268 563720.
This installation, or part of it, is
protected by a device which
automatically switches off the supply
if an earth fault develops.
Test quarterly by pressing the button
marked 'T' or 'Test'. The device
should switch off the supply and
should then be switched on to restore
the supply.
If the device does not switch off the
supply when the button is pressed,
seek expert advice.
OFF
ON
IMPORTANT
ALLMAINSWITCHES
MUSTBESWITCHED
OFFTOCOMPLETELY
DISCONNECTTHEUNIT
FROMTHESUPPLY
WARNING
DISCONNECTTHE
MAINSSUPPLY
BEFOREREMOVING
THISCOVER
WARNING
ENSUREALLTERMINAL
SCREWSAREFULLY
TIGHTENEDBEFORE
FITTINGFRONTCOVER
MKSENTRY
CONSUMERUNIT
TOBSEN60439-3
220-250V50Hz a.c.
RATEDCURRENT
MUSTNOTEXCEED
100AMAX
OFF
ON
WARNING
DISCONNECTTHE
MAINSSUPPLY
BEFOREREMOVING
THISCOVER
MKSENTRY
CONSUMERUNIT
TOBSEN60439-3
220-250V50Hz a.c.
RATEDCURRENT
MUSTNOTEXCEED
63AMAX
RCD
PROTECTED
CIRCUITS
TEST QUARTERLY
(Cut as required)
SENTRY CONSUMER UNIT - LABEL SHEET
Please leave any unused labels with the consumer
H Main Switches Warning Labels
4 module unit
8, 12, 16 & 21 module units
G Individual Circuit Labels
Fit to prominent position on or near
Consumer Unit.
MCB
On
Off
Mid-Trip
RCD
PROTECTED
CIRCUITS
TEST QUARTERLY
RCD
PROTECTED
CIRCUITS
TEST QUARTERLY
10
9
11
12
13
14
15
16
2
1
3
4
5
6
7
8
22
23
24
U1
U2
U3
RCD
TIMEDELAYED
1234567891011121314
Pantone
485
Pantone
102
Pantone
355
Pantone
Blue??
Pantone
Black
This proofhas been printed ona low resolution colourproofer.Coloursmay vary from final print.
Liability cannotbe accepted byPPL forerrors oromissionsonce the proof and job specification hasbeenapproved.
Ref:
Ono:
OurRef:
Date:
Version:
Size:
MKElectrics
22852
F641
25.03.08
v.2
228.6 x320
K6061SMET
K6062SMET
286
mkelectric.co.uk mkelectric.co.ukCIRCUIT PROTECTION
Sentry