2/80 FAK foot and palm switches
FAK
2010 CA08103002Z-EN
www.eaton.comFAK
Technical data
FAK foot and palm switch
FAK-R/V/KC11A/I
Momentary
Maintained
Maintained
General
Standards
IEC/EN 60947, VDE 0660
IEC/EN 60947, VDE 0660
IEC/EN 60947, VDE 0660
Lifespan, mechanical
Operations
x 10
6
1
0.1
0.1
Operating frequency
Operations/h
≦ 3600
≦ 600
≦ 600
Actuating force
N
20 - 40
40 - 60
15 - 25
Operating torque
Nm –
–
–
Protection type,
IEC/EN 60529
IP67, IP69K
IP67, IP69K
IP65
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Open
°C
-25 - +40
-25 - +40
-25 - +40
Mounting position
Any
Any
Any
Mechanical shock resistance to
IEC 60068-2-27 Shock duration 11 ms,
half-sinusoidal
g
> 15
> 15
> 15