Background Image
Table of Contents Table of Contents
Previous Page  83 / 336 Next Page
Information
Show Menu
Previous Page 83 / 336 Next Page
Page Background

2/80 FAK foot and palm switches

FAK

2010 CA08103002Z-EN

www.eaton.com

FAK

Technical data

FAK foot and palm switch

FAK-R/V/KC11A/I

Momentary

Maintained

Maintained

General

Standards

IEC/EN 60947, VDE 0660

IEC/EN 60947, VDE 0660

IEC/EN 60947, VDE 0660

Lifespan, mechanical

Operations

x 10

6

1

0.1

0.1

Operating frequency

Operations/h

≦ 3600

≦ 600

≦ 600

Actuating force

N

20 - 40

40 - 60

15 - 25

Operating torque

Nm –

Protection type,

IEC/EN 60529

IP67, IP69K

IP67, IP69K

IP65

Climatic proofing

Damp heat, constant, to IEC 60068-2-78

Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature

Open

°C

-25 - +40

-25 - +40

-25 - +40

Mounting position

Any

Any

Any

Mechanical shock resistance to

IEC 60068-2-27 Shock duration 11 ms,

half-sinusoidal

g

> 15

> 15

> 15