Background Image
Table of Contents Table of Contents
Previous Page  185 / 211 Next Page
Information
Show Menu
Previous Page 185 / 211 Next Page
Page Background

T ECHN I CAL DATA

C I RCU I T P ROT ECT I ON

185

CONTROL MODULES – GENERAL

l

L N

1

7

OK

MENU

+

AUTO ON

14 : 00

02 .

.

NOV 2010

L

N

L

L

1

8

O

10

4

N

N

O

L1

L2 1 4 2

L

N

1 2

L

N

4 3

5 I

Resistive Loads

3600W

Incandescent/Halogen 1000W

Motors

1000W

E S/L V Fluorescent

100W

Mains Halogen

1000W

L V Halogen

2300W

Incandescent/Halogen 1000W

Fluorescent

2500W

Motors

1000W

Mains Halogen

1000W

E S Lamps

150W

L V Halogen

150W

L V Fluorescent

150W

Incandescent 1000W

Halogen

1000W

Fluorescent

2500W

Mains Halogen 1000W

L V Halogen 2000W

Motors

1000W

Incandescent 1800W

Halogen

1800W

Fluorescent

2300W

Mains Halogen 1800W

L V Halogen 2300W

Motors

1800W

Low Energy 100W

Incandescent 1800W

Halogen

1800W

Fluorescent

2300W

Mains Halogen 1800W

L V Halogen 2300W

Motors

1800W

Low Energy 100W

Technical Data

301/TS11

301/TQ24

Supply Voltage

230V 50Hz

230V 50/60Hz

-

-

R100h/+25˚C

Power Consumption 1W

1W

Accuracy

50Hz

± 2 s/d

Switch Contacts

16A 250V~

cos

=1

16A 250V~

cos

=1

Terminal Capacity

Single strand 1- 4mm

2

Single strand 1- 4mm

2

Multi strand 0.5 - 2.5mm

2

Multi strand 0.5 - 2.5mm

2

Operating Temp.

-10˚C to +55˚C

-10˚C to +55˚C

Storage Temp.

-10˚C to +55˚C

-10˚C to +60˚C

Technical Data

301/TD1

Supply Voltage

230V 50/60Hz

Power Consumption

ca. 1W

Contact Rating

16A 250V~

cos

=1

Parallel compensation

not allowed

Accuracy

± 2.5 s/d

Terminal Capacity

Single strand 1- 4mm

2

Multi strand 1.5 - 2.5mm

2

Program pictures

8

Battery reserve

100h

Working ambient

-10˚C to +55˚C

Storage ambient

-10˚C to +60˚C

For safety, when the time switch is connected to the mains supply the contact should not be used on

an isolated low voltage supply. And when the time switch is connected to the isolated voltage supply

the contact should not be used on the mains supply.

L

1

N

1

7

C1 C2

2

OK

MENU

+

CHANNEL 1

AUTO ON

TUE 14 : 00

02 .

.

NOV 2010

L

N

Technical Data

302/TD2

Supply Voltage

230V 50/60Hz

Effective power Consumption

Approx. 1W

Contact Rating

2 changeover contact 16A

Parallel compensation

250V~

cos 60VA max.7 F

Accuracy

± 1 s/25˚C

Terminal Capacity

Single strand 1.5- 4mm

2

Multi strand 1.5 - 2.5mm

2

Programmes

28 per channel

Battery reserve

6 years

Working ambient

-20˚C to +55˚C

Storage ambient

-20˚C to +60˚C

Technical Data

302/TD1

Supply Voltage

230V 50/60Hz

Effective power Consumption

Approx. 1W

Contact Rating

1 changeover contact 16A

Parallel compensation

250V~

cos 60VA max.7 F

Accuracy

± 1 s/25˚C

Terminal Capacity

Single strand 1.5- 4mm

2

Multi strand 1.5 - 2.5mm

2

Programmes

56

Battery reserve

6 years

Working ambient

-20˚C to +55˚C

Storage ambient

-20˚C to +60˚C

Technical Data

303/TS24

303/TQ7 303/TQ24

Supply Voltage

230V 50Hz

230V 50/60Hz

-

-

R100h/+25˚C

Accuracy

50Hz

± 2 s/d

Switch Contact

16A 250V~

cos

=1

16A 250V~

cos

=1

Parallel compensation C

14 F

C

14 F

Terminal Capacity

Single strand 1- 4mm

2

Single strand 1- 4mm

2

Multi strand 0.5 - 2.5mm

2

Multi strand 0.5 - 2.5mm

2

Operating Temp.

-10˚C to +55˚C

-10˚C to +55˚C

Storage Temp.

-10˚C to +55˚C

-10˚C to +60˚C

Safety notes

This product may be installed only by a qualified electrician. Non-compliance may result in a fire hazard or electric shocks. Before installation, read the operating instructions and observe the product-specific requirements for the

installation location.

301/TS11 &

301/TQ24

303/TS24

303/TQ7 &

303/TQ24

301/TD1

302/TD1

302/TD2