317

Spacial SFP

Prisma functional system

Characteristics

Form 2 partitioning

Separation of busbars from the functional units:

b

b

protection against contact with live parts upstream of the outgoing circuits

b

b

protection against penetration of foreign solid bodies.

Lateral

partitioning

Form 2 restoration for

side-barrier cut-out

Partitioning

extension

Front and

rear barrier

Inter-cubicle

partitioning

DD384407.eps

DD384408.eps

DD384409.eps

DD384410.eps

Schemes

DD383356.EPS

DD385542.eps

DD383360.EPS

DD385543.eps

Characteristics

b

b

Vertical barrier made

of insulating slats.

b

b

Can be installed on

both sides of Linergy and

flat busbars.

b

b

The space between

the slats is sufficient for

prefabricated

connections (one copper

bar, 5 or 10 mm thick, or

insulated flexible bars) or

for cables up to 35 mm²,

while maintaining the

degree of protection

IP2X compliance with

standard IEC 60695.2.1

concerning withstand to

fire.

b

b

This kit enables passage

of the connection between

a device > 1600 A (NW,

INS) and lateral vertical

busbars.

b

b

It is made up of an

insulated plate (six modules

H 300 mm) that can be cut

as required, supplied with

supports and the necessary

hardware.

b

b

For the Spacial SFP

system switchboards 600

and 800 mm depth,

a partitioning extension

is required.

b

b

Front protection is

realized by the

association of the door

W300 and this barrier.

Metallic barrier,

composed of 2 parts

H850, pre-cut at both

ends.

b

b

Rear protection, a

barrier is required at the

rear of the busbar

compartment in cubicles

that are 800, 1000 and

1300 mm deep.

b

b

Metal partition, used to

separate two adjacent

cubicles.

b

b

It is made up of two panels,

each 850 mm high.

b

b

The top and bottom ends

have knock-outs for horizontal

busbars.

b

b

Supplied with the

necessary supports and

hardware, the partition is

mounted on the framework

and does not hinder

installation of the functional

mounting plates.

Referencias 06545

04924

D600:

06541

D800:

06543

06540

D500:

06555

D600:

06565

D800:

06558

Partitioning of horizontal busbars

DD384412.eps

DD384411.eps

W300

W700

Designation

b

b

Set of two barriers (front and rear), plus a slotted rear panel for efficient natural convection in the switchboard.

b

b

The set can be used to partition horizontal busbars installed at the top or bottom of the cubicle.

b

b

The space required for the busbars is not increased.

For Depth

D500

D600

D800

D500

D600

D800

Cat. no. for 3M

busbar

06560

06561

06563

06570

06570

06570

Cat. no. for 4M

busbar

06568

06568

06568

06567

06567

06567

Note:

when the busbars are at the bottom of the cubicle, gland plates are mandatory.