IP 67 conforms to BS EN 60529 and IEC 60529
IK 09 conforms to BS EN 62262 and IEC 62262
External screws in stainless steel
Icc 10 kA conforms to BS EN 60309-1, BS EN 60309-2 and
IEC 60309-1, IEC 60309-2
Self-extinguishing : 850 °C for insulated parts (650 °C for housing)
according to BS EN 60695-1, BS EN 60695-2, IEC 60695-1
and IEC 60695-2
n
Single socket units with switch
(p. 191)
Cat. Nos. 0591 14/15
125 A
n
Single socket units with
2
rail or MCB /
protected by 30 mA RCBO or RCD
(p. 191)
E
Fix C
Fix C1
Fix D
CE1
CE2
CE3
CE1
CE2
CE3
Fix D1
F
H
B
6
CE4
CE
CE
10
G
A
Ø 6
Ø 6
083970-7853c.eps
Fix C
Fix C1
Fix D1
Fix D
B
F
CE1
CE2
CE1
CE2
A
E
G
10
6
CE3
CE
CE
H
Ø 6
Ø 6
083973-7859c.eps
Cat. Nos.
Dimensions (mm)
Knock-out entries
for cable gland
200 to 380 to
A B C D C1 D1 E F G H
α
CE1 CE2 CE3 CE4
250 V
±
415 V
±
2P+
T
0592 60
151
0
3P+
T
0592 61
151
0
3P+N+
T
0592 62 120 230 106 216 70 190 151 25 20 2 46°
2P+
T
0592 63
152
8
3P+
T
0592 64
152
8
3P+N+
T
0592 65
152
12
3P+
T
0592 66
170 320 156 306 100 270 204 65 28 18 56°
M20
3P+N+
T
0592 67
63 A
32 A
16 A
M20/
M25
M20/
M25
M25/
Ø29
M25/
Ø38
–
M20/
M25
M25/
M32
Cat. Nos.
Dimensions (mm)
Knock-out entries
for cable gland
110 to 200 to 380 to
A B C D C1 D1 E F G H
α
CE1 CE2 CE3
130 V
±
250 V
±
415 V
±
2P+
T
059660 059661/51
151
0
3P+
T
059652
151
0
3P+N+
T
059653 140 370 126 356 74 330 151 95 20 2 46°
2P+
T
059655
152
8
3P+
T
059667/57
152
8
3P+N+
T
059668/58
156
12
3P+N+
T
059681 160 470 146 456 90 420 204 125 28 17 56°
M25/
M32
M25/
M32
M20/
M25
M20/
M25
63 A
32 A
16 A
M25/
Ø29
M25/
M38/
Ø38
370
356
300
230
216
150
M40
M40 M50
M50
Ø 6 . 2
Ø 6 . 2
6 . 2
254
10
41 (M50)
38 (M40)
50°
324
n
Technical information
n
Single socket units with switch (continued)
(p. 191)
n
Connection and protection
Connecting socket bases
Cross section of cables inside the unit according to the current used :
Socket 16 A : 2 . 5 mm
2
Socket 32 A : 6 mm
2
Socket 63 A : 16 mm
2
Types of protection and number of modules
Upstream, Hypra equipped or to-be-equipped units can integrate,
according to catalogue numbers, modular protective devices of various
kinds :
Legrand MCBs, RCBOs and RCDs
NB :
according to the required use, it is essential to check that the
protection against indirect contacts (residual current) and the protection
against overloads and short circuits (Legrand circuit breakers) are both
well covered
Caution :
a residual current device (RCD) does not provide protection
against overloads and short circuits
Short circuit withstand :
for the short circuit withstand of MCBs,
RCBOs and RCDs, refer to the performance pages for these products in
the relevant section of this catalogue
Ratings for units equipped with residual current device (RCD) :
Ratings
Sensitivity
16 A ................ RCD 25 A
30 mA
32 A ................ RCD 40 A
30 mA
63 A ................ RCD 63 A
30 mA
Hypra
®
IP 66/67-55 combination units - LV 16/32/63/125 A
p
lastic surface mounting