IP 44 conforms to BS EN 60529 and IEC 60529
IK 09 conforms to BS EN 62262 and IEC 62262
External screws in stainless steel - Nickel plated contacts
Icc 10 kA conforms to BS EN 60309-1, BS EN 60309-2 and
IEC 60309-1, IEC 60309-2
Self-extinguishing : 850 °C for insulated parts (650 °C for housing)
according to BS EN 60695-1, BS EN 60695-2, IEC 60695-1
and IEC 60695-2
IK 09
RAL 7022
Units with Prisinter :
• IP 44 plug connected conforms to BS EN 60529 and IEC 60529
• IP 55 with cover closed or used with IP 66/67-55 plug
• Breaking capacity conforms to BS EN 60947-1, BS EN 60947-3,
IEC 60947-1 and IEC 60947-3 :
n
Single socket units with switch
(p. 190)
n
Technical information
n
Single socket units protected by 30 mA RCBO and Prisinter single socket units protected by 30 mA RCBO
(p. 190)
n
Single socket units with switch and protected by 30 mA RCBO or RCD
(p. 190)
16 A
32 A
63 A
AC1
16 A - 400 V
±
32 A - 400 V
±
63 A - 400 V
±
AC3
8·4 kW
16·8 kW
33 kW
AC23
8·4 kW
16·8 kW
33 kW
Fix C
Fix C1
6
CE1
CE2
CE3
CE1
CE2
CE3
CE
H
CE4
A
Fix D
B
E
Fix D1
F
10
G CE
Ø 6
Ø 6
083968-7862c.eps
Fix C
Fix C1
6
CE1
CE2
CE3
CE1
CE2
CE3
CE
H
CE4
A
E
B
Fix D1
F
Fix D
10
G
CE
083968-7863c.eps
Ø 6
Ø 6
Fix C
Fix C1
Fix D
B
F
Fix D1
CE1
CE2
CE1
CE2
A
E
G
10
6
CE3
CE
CE
H
083972-7864c.eps
Ø 6
Ø 6
Cat. Nos.
Dimensions (mm)
Knock-out entries
for cable gland
110 to 200 to 380 to
A B C D C1 D1 E F G H
α
CE1 CE2 CE3 CE4
130 V
±
250 V
±
415 V
±
2P+
T
0592 00 0592 03
0
3P+
T
0592 09
0
3P+N+
T
0592 16
120 230 106 216 70 190 151 25 20
1·5
46°
2P+
T
0592 43
9
3P+
T
0592 49
9
3P+N+
T
0592 56
10
3P+
T
0592 34
170 320 156 306 100 270 204 65 28 21·5 56°
3P+N+
T
0592 35
63 A
32 A
16 A
M
20/25
M
25/32 M 20
M
20/25
M
20/25
–
Ø 38
Ø 29
M
25/32
M
20/25
Ø 38
Cat. Nos.
Dimensions (mm)
Knock-out entries
for cable gland
200 to
380 to
A B C D C1 D1 E F G H
CE1 CE2 CE3 CE4
250 V
±
415 V
±
2P+
T
0592 07
132
0
3P+
T
0592 14
134
0
3P+N+
T
0592 19
138
1·5
2P+
T
0592 47
120 230 106 216 70 190
145
25 20
9
46°
3P+N+
T
0592 59
148
10
2P+
T
0592 24
195
0
3P+
T
0592 25 170 320 156 306 100 270 195 65 28 0 56°
3P+N+
T
0592 26
202
0
3P+
T
0592 28
170 320 156 306 100 270
206
65 28
0
56°
3P+N+
T
0592 29
214
0
32 A 16 A
32 A 16 A
Prisinter
M
20/25
–
M
20/25
M
25/32 M 20
M
20/25
Ø 38
Ø 29
Cat. Nos.
Dimensions (mm)
Knock-out entries
for cable gland
200 to
380 to
A
B
C
D C1 D1 E
F
G
H
α
CE1 CE2 CE3
250 V
±
415 V
±
Protected by 30 mA RCBO
2P+
T
0596 01
0
3P+
T
0596 02
0
3P+N+
T
0596 03
140 370 126 356 74 330 151 95 20
1·5
46°
2P+
T
0596 05
9
3P+
T
0596 07
9
3P+N+
T
0596 08
10
Protected by RCD
3P+
T
0596 83
160 470 146 456 90 420 204 125 28 20 56°
3P+N+
T
0596 84
63 A 32 A
16 A
M
20/25
M
20/25 Ø 29
Hypra
®
IP 44 combination units - LV 16/32/63 A
p