5.14

General Catalogue • Modular Devices

Light Sensitive Switch

Light Sensitive Programmer

Description

A photo-electric cell measures

the light level and in conjunction

with the relay provides on/off

control of a circuit.

This device controls lighting

circuits in relation to ambient

light, based on user settings.

Front cover sealability

Applications

Street lighting, display lighting,

illuminated signs etc.

Connection

Protected cable clamps

Capacity:

Rigid: 1.5 to 10mm

2

Flexible: 1 to 6mm

2

On board LED shows status of

changeover contact.

Technical Data

4 position override switch

allowing:

• Auto: normal operating mode

• On: permanently switched on

• Off: permanently switched off

• Test: setting mode for easy

adjustment.

3 Mod = 52.5mm

Light Sensitive Switch

2 sensitivity ranges: 5 to 50 lux, 50 to 2000 lux

Delivered with a separate surface photo-electric cell EE003

Must be used in conjunction with a suitably rated contactor (page 5.7- 5.8) where load conditions

demand

Characteristics

Width

Cat ref.

Voltage rating: 230V~ 50/60Hz

3 Mod

EEN100

Outputs: 1 changeover AC 1 contact 16A AC1 - 230V~

Maximum distance: 50m between photocell and controller

Description

To control the lighting installation

in relation to time and ambient

light.

It is a weekly programmer

associated with a light sensitive

switch.

Working Principle

The user programmes both on/

off periods and a desired light

level. The cell measures the

light level within the on period.

Depending on the light level

(below or above the

programmed threshold, the

output will be switched on/off.

20 program steps, 1 minute

switching increments

Programming Function

Programming by keys and

display on LCD screen.

On/off override facility,

permanent working.

Display and control of the

programme.

Test setting for easy adjustment.

1 Mod = 17.5mm

3 Mod = 52.5mm

Light Sensitive Programmer

2 sensitivity ranges: 5 to 50 lux, 50 to 2000 lux

Delivered with a separate surface photo-electric cell EE003

Must be used in conjunction with a suitably rated contactor (page 5.7 - 5.8) where load conditions

demand

Characteristics

Width

Cat ref.

Voltage rating: 230V~ 50/60Hz

3 Mod

EE171

Outputs: 1 changeover AC 1 contact 16A AC1 - 230V~

Maximum distance: 50m between photocell and controller

Replacement Photo Electric Cell

Mounting

For Cat ref.

Pack qty.

Cat ref.

Flush

EEN100, EE171

1

EE002

Surface

EEN100, EE171

1

EE003

EE003

EE171

EEN100