Background Image
Table of Contents Table of Contents
Previous Page  75 / 108 Next Page
Information
Show Menu
Previous Page 75 / 108 Next Page
Page Background

75

technical hotline +44 (0)1268 563720

overhead systems

Interact Overhead Power

Part No.

Description

UK2

Hanging Bracket to suit up to ø10mm tie rod

UK2E

Hanging Bracket with 50mm x 50mm Trunking Suspension Arm

UK4

Hanging Bracket with Hook

UKDC

Additional Dust Cover

Please refer to Interact Overhead Power Technical – page 115, for details regards support

bracket spacing and maximum suspended load.

Tap-off Leads

Type

Pin Position

CURRENT

RATING

Protection 1 metre

3

metre

5

metre

Key Code

2.5

mm

2

2.5

mm

2

2.5

mm

2

SINGLE PHASE

N1 L1

PE

25

A Unfused

LT12501C

LT32501C

LT52501C

16

A Fused

LT11601C

LT31601C

LT51601C

N1

L2

PE

25

A Unfused

LT12502C

LT32502C

LT52502C

16

A Fused

LT11602C

LT31602C

LT51602C

N1

L3 PE

25

A Unfused

LT12503C

LT32503C

LT52503C

16

A Fused

LT11603C

LT31603C

LT51603C

L4 N1

PE

25

A Unfused

LT12504C

LT32504C

LT52504C

SINGLE PHASE +L4

L4 N1 L1

PE

25

A Unfused

LT12521C

LT32521C

LT52521C

L4 N1 L1

(

F)

PE

16

A Fused

LT11621C

LT31621C

LT51621C

L4 N1

L2

PE

25

A Unfused

LT12522C

LT32522C

LT52522C

L4 N1

L2

(

F)

PE

16

A Fused

LT11622C

LT31622C

LT51622C

L4 N1

L3 PE

25

A Unfused

LT12523C

LT32523C

LT52523C

L4 N1

L3

(

F)

PE

16

A Fused

LT11623C

LT31623C

LT51623C

ALL PHASE

N1 L1 L2 L3 PE

25

A Unfused

LT12505C

LT32505C

LT52505C

ALL PHASE + L4

L4 N1 L1 L2 L3 PE

20

A Unfused

LT12506C

LT32506C

LT52506C

CIRCUIT 1 GREY

PE1 N1 L1

25

A Unfused

LT12501GRY

LT32501GRY

LT52501GRY

16

A Unfused

LT11601GRY

LT31601GRY

LT51601GRY

CIRCUIT 2 GREY

N2 L2 PE2

16

A Unfused

LT11625GRY

LT31625GRY

LT51625GRY

25

A Unfused

LT12525GRY

LT32525GRY

LT52525GRY

DUAL GREY

PE1 N1 L1 N2 L2 PE2

20

A Unfused

LT12526GRY

LT32526GRY

LT52526GRY

(

F) = Fused.

LSF Cable is supplied as standard. For PVC cable replace suffix ‘C’ with suffix ‘PVC’. For Dual Grey system simply add suffix ‘PVC’. Suffix must be added when ordering.

Polarity of tap-offs are configured to enable L4 to be used as a continuous conductor for Emergency Line.

When using tap-offs ensure that the line is protected by an appropriately rated protective device.

Key codes shown are from the perspective of the powertrack socket with the keycode in the top right corner.

The tap-off key code will be a mirror image when viewed from underneath.

Other components