Switch Disconnectors
3NJ62 In-Line Switch Disconnectors with Fuses up to 630 A
Introduction
7/91
Siemens LV 10 · 2014
■
Benefits
Key advantages for switchgear manufacturers
due to the following:
• Compact, modular design
• Simple and efficient mounting due to incoming plug-in contact
• High packing density in the field
• Cable connection with cable clamps or cable lugs
• Can be mounted in different control cabinet depths
• Comprehensive range of accessories
The advantages for users are:
• Conversion, retrofitting and replacement
without switching off the switchgear
• Dead-state fuse replacement
• Maintenance-free
• High personal safety
• Operating handle can be locked in OFF position
• Clear and unambiguous switch position indicator
■
Application
The plug-in 3NJ6 switch disconnectors with fuses are installed
in low-voltage distribution boards where a minimum amount of
space is available for a maximum number of cable ducts to the
power distribution. They can be easily fitted in all common con-
trol cabinets (minimum depth: 400 mm).
The plug-in 3NJ62 switch disconnectors with fuses are available
for rated uninterrupted currents from 160 A to 630 A.
LV HRC fuse links according to IEC 60269-1/EN 60269-1 (sizes
NH 00 to NH 3) or BS fuse links according to BS 88 provide over-
load and short-circuit protection up to 690 V AC.
The switch disconnectors can be retrofitted at any time with aux-
iliary switches, an ammeter (48 mm x 48 mm) and current trans-
formers, with no extra space required. For installation in control
cabinets of > 400 mm depth, the mounting depth of the discon-
nectors can be increased by 200 mm using a contact extension.
Further installation accessories, such as guide rails and blank-
ing covers, complete the product range.
■
Function
Fuse monitoring
Fuse monitoring is used to detect, indicate and report faults.
The electronic fuse monitoring devices are available in
2 versions.
EFM 10 electronic fuse monitoring devices:
• For use up to 690 V AC
• Operational voltage < 20 V
• Display: ready-to-run
• Individual fault display per phase
• 1 CO contact as centralized fault signaling unit
EFM 20/25 electronic fuse monitoring and line monitoring
devices:
• EFM 20 for use up to 690 V AC, EFM 25 for use up to 440 V DC
• Operational voltage < 13 V (EFM 20) < 20 V (EFM 25)
• Test function
• Closed-circuit principle or open-circuit principle
• 2 CO contacts as centralized fault signaling unit incl. line
monitoring functions with phase failure detection (EFM 20),
undervoltage/overvoltage detection
EFM 10 electronic fuse monitoring device
EFM 20/25 electronic fuse monitoring device