4-pole
2/40
Siemens LV 10.1 · 2011
* You can order this quantity or a multiple thereof.
1)
Front busbar connection pieces are included in the scope of supply and
are to be fitted by the customer.
Type
Rated
current
I
n
Current setting of the
inverse-time delayed
overcurrent releases
"
L
"
I
R
Operating current of
the instantaneous
short-circuit releases
"
I
"
I
i
DT
I
cu
up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
For price
see page
2/54
PU
(UNIT,
SET, M)
PS*/
P. unit
PG Weight
per PU
approx.
Order No. supplement
required,
see page 2/57
A
A
A
kg
4-pole, fixed-mounted, for system protection,
63 A to 1600 A, electronic releases LI
ETU10, LI function
With adjustable overcurrent releases, adjustable short-circuit releases
VL160/3VL2
63
25 ... 63
1.25 ... 11 ×
I
n
B
3VL27 06-1
@@
4
@
-....
1 1 unit 113 3.100
100
40 ... 100
1.25 ... 11 ×
I
n
B
3VL27 10-1
@@
4
@
-....
1 1 unit 113 3.100
160
64 ... 160
1.25 ... 11 ×
I
n
B
3VL27 16-1
@@
4
@
-....
1 1 unit 113 3.100
VL250/3VL3
200
80 ... 200
1.25 ... 11 ×
I
n
B
3VL37 20-1
@@
4
@
-....
1 1 unit 113 3.300
250
100 ... 250
1.25 ... 11 ×
I
n
B
3VL37 25-1
@@
4
@
-....
1 1 unit 113 3.300
VL400/3VL4
315
128 ... 315
1.25 ... 11 ×
I
n
B
3VL47 31-1
@@
46-....
1 1 unit 113 7.600
400
160 ... 400
1.25 ... 11 ×
I
n
B
3VL47 40-1
@@
46-....
1 1 unit 113 7.600
VL630/3VL5
630
252 ... 630
1.25 ... 10 ×
I
n
B
3VL57 63-1
@@
46-....
1 1 unit 113 11.700
VL800/3VL6
800
320 ... 800
1.25 ... 8 ×
I
n
B
3VL67 80-1
@@
46-....
1 1 unit 113 20.500
VL1250/3VL7 1000
400 ... 1000
1.25 ... 11 ×
I
n
B
3VL77 10-1
@@
46-....
1 1 unit 113 33.500
1250
500 ... 1250
1.25 ... 11 ×
I
n
B
3VL77 12-1
@@
46-....
1 1 unit 113 33.500
VL1600/3VL8
1)
1600
640 ... 1600
1.25 ... 9 ×
I
n
B
3VL87 16-1
@@
40-....
1 1 unit 113 40.800
4-pole, fixed-mounted, for system protection,
63 A to 1600 A, electronic releases LIN
ETU10, LIN function
With adjustable overcurrent releases, adjustable short-circuit releases,
with overcurrent and short-circuit release in 4th pole (N)
N protection = 50/100 %
VL160/3VL2
63
25 ... 63
1.25 ... 11 ×
I
n
B
3VL27 06-1
@@
4
@
-....
1 1 unit 113 3.100
100
40 ... 100
1.25 ... 11 ×
I
n
B
3VL27 10-1
@@
4
@
-....
1 1 unit 113 3.100
160
64 ... 160
1.25 ... 11 ×
I
n
B
3VL27 16-1
@@
4
@
-....
1 1 unit 113 3.100
VL250/3VL3
200
80 ... 200
1.25 ... 11 ×
I
n
B
3VL37 20-1
@@
4
@
-....
1 1 unit 113 3.300
250
100 ... 250
1.25 ... 11 ×
I
n
B
3VL37 25-1
@@
4
@
-....
1 1 unit 113 3.300
VL400/3VL4
315
128 ... 315
1.25 ... 11 ×
I
n
B
3VL47 31-1
@@
46-....
1 1 unit 113 7.600
400
160 ... 400
1.25 ... 11 ×
I
n
B
3VL47 40-1
@@
46-....
1 1 unit 113 7.600
VL630/3VL5
630
252 ... 630
1.25 ... 10 ×
I
n
B
3VL57 63-1
@@
46-....
1 1 unit 113 11.700
VL800/3VL6
800
320 ... 800
1.25 ... 8 ×
I
n
B
3VL67 80-1
@@
46-....
1 1 unit 113 20.500
VL1250/3VL7 1000
400 ... 1000
1.25 ... 11 ×
I
n
B
3VL77 10-1
@@
46-....
1 1 unit 113 33.500
1250
500 ... 1250
1.25 ... 11 ×
I
n
B
3VL77 12-1
@@
46-....
1 1 unit 113 33.500
VL1600/3VL8
1)
1600
640 ... 1600
1.25 ... 9 ×
I
n
B
3VL87 16-1
@@
40-....
1 1 unit 113 40.800
N
L
I
NSE0_00691
1.0
Alarm
Active
>1.05
X3
x
I
n
R
I
17
14
20
(S)
R
t
30
25
10
8
6
4
6
8
x
I
n
5 4
3
2
10
i
I
11
NSE0_02119
.5
.8
.7 .63
.9
.6
.45
.4
.95
2.5
1.25
1.5
>
Connection type can be selected by assignment of the 12th position of the Order No.
• Connection with box terminal
3
• Connection with screw terminal
6
>
• Without communication preparation
TB
• With communication preparation
NB
L
I
NSE0_00691
1.0
Alarm
Active
>1.05
X3
x
I
n
R
I
17
14
20
(S)
R
t
30
25
10
8
6
4
6
8
x
I
n
5 4
3
2
10
i
I
I
I
I
11
N
N
50%
N
100%
NSE0_02077
.5
.8
.7 .63
.9
.6
.45
.4
.95
2.5
1.25
1.5
>
Connection type can be selected by assignment of the 12th position of the Order No.
• Connection with box terminal
3
• Connection with screw terminal
6
>
• Without communication preparation
TA
• With communication preparation
NA
• Marine engineering-certified LRS, DNV and GL (not communication-ready)
LA
Z