Background Image
Table of Contents Table of Contents
Previous Page  36 / 98 Next Page
Information
Show Menu
Previous Page 36 / 98 Next Page
Page Background

4-pole

2/36

Siemens LV 10.1 · 2011

* You can order this quantity or a multiple thereof.

**

Delivery time class A for Order No. supplement "0AA0", see page 2/57.

Type

Rated

current

I

n

Current setting of the

inverse-time delayed

overcurrent releases

"

L

"

I

R

Operating current of the

instantaneous

short-circuit releases "

I

"

I

i

DT

**

I

cu

up to 55 kA at 415 V, standard switching capacity N

See "Overview".

Order No.

Basic price

per PU

PU

(UNIT,

SET, M)

PS*/

P. unit

PG Weight

per PU

approx.

Order No. supplement

required,

see page 2/57

A

A

A

kg

4-pole, fixed-mounted, for system protection, 16 A to 160 A,

thermal-magnetic releases LIN

System protection, TM, LIN function

With non-adjustable thermal overcurrent releases, non-adjustable short-circuit releases,

with "N" overcurrent and short-circuit release

N protection = 100 %

VL160X/3VL1 16

16

300

B

3VL17 96-1EA4

@

-....

1 1 unit 113 2.300

20

20

300

B

3VL17 02-1EA4

@

-....

1 1 unit 113 2.300

25

25

300

B

3VL17 25-1EA4

@

-....

1 1 unit 113 2.500

32

32

300

B

3VL17 03-1EA4

@

-....

1 1 unit 113 2.500

40

40

600

B

3VL17 04-1EA4

@

-....

1 1 unit 113 2.500

50

50

600

B

3VL17 05-1EA4

@

-....

1 1 unit 113 2.500

63

63

600

B

3VL17 06-1EA4

@

-....

1 1 unit 113 2.500

80

80

1000

B

3VL17 08-1EA4

@

-....

1 1 unit 113 2.500

100

100

1000

B

3VL17 10-1EA4

@

-....

1 1 unit 113 2.500

125

125

1000

B

3VL17 12-1EL4

@

-....

1 1 unit 113 2.500

160

160

1500

B

3VL17 16-1EL4

@

-....

1 1 unit 113 2.500

System protection, TM, LIN function

With non-adjustable thermal overcurrent releases, non-adjustable short-circuit releases,

with "N" overcurrent and short-circuit release

N protection = 60 %

VL160X/3VL1 125

125

1000

B

3VL17 12-1EA4

@

-....

1 1 unit 113 2.500

160

160

1500

B

3VL17 16-1EA4

@

-....

1 1 unit 113 2.500

N

NSE0_00695

63A

OFF

CAT.A

50° C

TM

~

=

NSE0_00539a

2

4

6

>

Connection type can be selected by assignment of the 12th position of the Order No.

• Connection with box terminal

3

• Connection with screw terminal not in conjunction with RCD module

6

NSE0_00695

63A

OFF

CAT.A

50° C

TM

~

=

NSE0_00539a

2

4

6

>

Connection type can be selected by assignment of the 12th position of the Order No.

• Connection with box terminal

3

• Connection with screw terminal not in conjunction with RCD module

6