WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION

PG00400018U – March 2012

Consumer unit solutions

There are many ways of providing RCD circuit protection to meet the demands of the new regulations.

The most comprehensive solution would be to provide individual RCBO protection on each

and every out going circuit from a consumer unit. Hence the use of a consumer unit such as a

12 way isolator controlled board. eg.

EAD12

fitted with up to

12 x RCBOs

or the

EAD11R

11

way unit with additional cabling space to accommodate the RCBOs.

The next level down would be to provide an isolator controlled dual RCD consumer unit

feeding two RCD board sections. eg.

EAD12H80H80D or EAD12H80H63D

fitted with up to

12 x MCBs

Such a dual RCD board could also be provided with some unprotected ways controlled by the

main switch to enable a supply to any individual circuits that don’t require RCD protection or

else require individual RCBO circuit protection.eg.

EAD12H80H803D or EAD12H80H633D

fitted with up to

15 x MCBs

A conventional split load board such as an

EAD14H80D

could have additional RCBOs fitted

to the non protected side allowing a mixture of Group RCD protected circuits and Individual

RCBO protected circuits.

Consumer units are already available with RCD incomers of 30mA sensitivity such as

EAD12H80, EAD12H100

. However, single RCD controlled units on their own are unlikely to

satisfy regulation 314.1 and 2.

Product overview

Memera consumer units and devices