WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION

PG00400018U – March 2012

25

Product overview

Memera consumer units and devices

1.4

Memera moulded consumer units – quick and easy installation

Step 1 – Prepare for base installation

On removal of the main cover using the quick release cover fasteners, the

complete pan assembly can be withdrawn from the base by means of the

unique clip feature. The busbar is then removed from its retaining clip.

Step 2 – Cut-out and cable preparation

Using any of the easily removable cut out sections, the cables may be prepared.

The empty base is then fitted to the wall without obstruction to the cable bunch..

Step 4 – Internal wiring

On re-fitting of the pan assembly, the pre-prepared cables can be wired to the

devices. Circuit testing can then be carried out at the appropriate time.

Step 3 – Pan assembly preparation

MCBs and RCBOs are fitted to the pan assembly in the appropriate positions.

The busbar is then snapped to the required length (split load units only) and fixed to

the device terminals. On completion the pan assembly is clipped into position.

Step 5 – Completion of internal wiring and labelling

Once all wiring is completed, the push-fit busbar cover is slotted

into position and the internal labels can be applied.

Step 6 – External identification labels and fitting of main cover

The external circuit identification labels are now applied. The cover is

then replaced easily and quickly using the quarter turn fasteners.