TECHN I CAL DATA

L MCCB

234

100

10

4

10

5

10

6

10

7

10

8

10

3

1000

10000

PROSPECTIVE CURRENT

100000

I

2

t

54.5

24.5

58.9

17.5

206

70 70

40

70

208

53 102

Terminal Extensions

250 - 400

A, A = 30

500 - 800

A, A = 50

MCCB supplied with

2

interphase barriers

40

257.2

232

14.3

29.7

232

100

85 92

278

A

8

POWERSTAR LS & LH FRAME MAXIMUM EARTH LOOP IMPEDANCES Zs (ohms) for

U

o

= 240V~

Current Rating (A)

250

315

400

500

630

800

Magnetic Trip Setting

0.4

Seconds Disconnection Time

0.0872

Ω

0.0692

Ω

0.0545

Ω

0.0436

Ω

0.0346

Ω

0.0272

Ω

High

5.00

Seconds Disconnection Time

0.1745

Ω

0.1385

Ω

0.1363

Ω

0.1090

Ω

0.0865

Ω

0.0681

Ω

Low

LS & LH FRAME MCCB s TECHNICAL SPECIFICATION

l

L FRAME SPECIFICATION

I

Specification

BSEN60947-2

Current Range

250 – 800

Amps

Ue Rated Operation Voltage

415

V

Ui Rated Insulation Voltage

660

V AC

Rated Frequency

50/60

Hz

Icu (415V) Short Circuit Breaking Capacity LS-32kA, LH-50kA

Release

Thermal Magnetic

Thermal Adjustment

70 – 100%

Rated Current

Instantaneous Adjustment

Adjustable – see below

Ambient Range

-20

°C to 55°C

Humidity Range

0 – 90%

Weight

TP – 9.2Kg TP & Sw N – 11.6Kg

L FRAME FEATURES

I

From J Frame to N Frame Powerstar MCCB’s

feature escutcheons of the same height to

simplify switchboard installations.

Front adjustable thermal and instantaneous

tripping elements

AVAILABLE OPTIONS

I

ST UVR

Aux SW

Key Interlock Direct Mounting

Rotary Handle

Padlocking

Dolly Extension

• 4

th Poles when fitted are left hand side

(

See Product Section for selection)

SHORT CIRCUIT BREAKING CAPACITY

I

Ue

Icu

220

V

40

kA

380

V

32

kA

415

V

32

kA

Ics

= 50% Icu

with correct line ‘load’ connection

MAGNETIC TRIP BANDS

I

Magnetic – (250 – 315A) Adjustable 5 – 10x In

– (400 – 800

A) Adjustable 4 – 10x In

TERMINALS

I

Cranked front connection terminals c/w M12

connection bolts for direct coupling of cable

sockets. Supplied with 2 interphase barriers.

AUXILIARY EQUIPMENT OPTIONS

I

L Frame MCCBs

a) UVR & Auxiliary Switch

b) Shunt Trip & Auxiliary Switches

c) Two Auxiliary Switches

Note: All Shunt Trips supplied with coil disconnection Auxiliary Switch.

Shunt Trip Voltage Range

70 – 110%

UVR Power Pack10VA

(110

V & 415V units supplied with Transformer in addition to Powerpack.).

Auxiliary Contacts

Volts Resistive Tungsten Load Inductive

Load (A) NC (A) NO (A) Load (A)

AC

125 15

1.5 1.0

5

250 15

0.7 0.5

5

DC

30 2

3

1.5

1

50 0.7

0.7 0.7

0.5

125 0.5

0.4 0.4

0.03