HEAT I NG , L I GHT I NG & M I N I CONTACTOR S

1757

C3/C7 TRIPLE POLE MINI CONTACTORS

l

RATING PER POLE (A)

AUXILIARY POLES

AC1

Approx motor

non

AC3

kW rating at

TYPE

inductive inductive 400/415V 3Ph N/O N/C

LIST No

AC COIL OPERATED

C3

20

5

2.2

1

41400/

Z_

1

41400/

Y_

C7

20

8.5

4

1

42400/

Z_

1

42400/

Y_

41400/

ZB

40000/

M2X

40000/

M4B

C3/C7 AUXILIARY CONTACT BLOCKS

l

4

A 400/415V AC15

CONTACTS

Mini Contactor Control Relay

TYPE

Normally open Normally closed LIST No

LIST No

2

pole

2

40000/

M2S

40600/

C2S

1

1

40000/

M2X

40600/

C2X

2

40600/

C2T

4

pole

4

40600/

C4N

1

3

40000/

M4P

40600/

C4P

2

2

40000/

M4B

40600/

C4B

3

1

40000/

M4C

40600/

C4C

4

40600/

C4A

Suitable for C3 & C7

Suitable for C7 only

Contactor

Enclosure

AMPS PER POLE

Heating and general

Mixed LIST

For one contactor

For two contactors (or one with

mixed loads.

Load

No.

with or without

space for control module)

Slightly Inductive

(220/240

V)

Switch disconnector

with or without Switch disconnector

AC1 duty (A)

(

A)

50

Hz Coil

LIST No.

LIST No.

Type C19

25

15

55400/

ZB

Type C30

35

20

57400/

ZB

Type C43

75

45

48400/

XB

TypeC63

85

55

49400/

XB

ACCESSORIES

l

Paralleling links

available for single pole switching for the following contactors (2 sets required per contactor):

Current carrying capacity

Maximum

LIST No.

Contactor type

Amps (AC1 duty)

cable size

C30

60

16

mm

2

56000/

ZK

C43/C63

120

50

mm

2

49000/

ZK

Neutral terminal

Space is provided for a proprietory neutral terminal.

Dimensions – see pages 260–261 Specification – see pages 241–242 Alternative coils – see page 181

HEATING & LIGHTING CONTACTORS

up to 85A

l

For example TP & N enclosed contactor with switch disconnector to control 85A heating load (AC1 duty): contactor

49400/

XB

,

enclosure

49011/

AA1

,

If additional space is required in the enclosure for control modules etc, select enclosure

49011/

AE1

.

49000/

ZK

1

Check rating required and select contactor.

Enclosures: IP66, comprising Steel back box and Polycarbonate cover. Except

*

which comprise IP55 Steel cabinet and hinged gasketed door.

2

Choose enclosure with or without MCS for one contactor or two

(

or one with space for Control Module).

57001/

AA1

57011/

AA1

}

with Switch

disconnector

57001/

AB1

57011/

AC1

}

with Switch

disconnector

49001/

AA1

49011/

AC1

}

with Switch

disconnector

49001/

AC1*

49011/

AE1*

}

with Switch

disconnector

49400/

XB

49001/

AA1

49011/

AE1