Table of Contents Table of Contents
Previous Page  500 / 578 Next Page
Information
Show Menu
Previous Page 500 / 578 Next Page
Page Background

Aluminium columns

Suitability tables

Celest/Civic/Oracle

Post Top Ø60/76mm

Luminaire Mount

SAP Code Catalogue No.

Height

(m)

Luminaire

Maximum

Weight (kg)

Shaft diameter

(mm)

Luminaire MaximumWind Area m

2

for

Rationalised Wind Loading Factor, Rwf N/m

2

Light

396

Medium

429

Heavy

466

X Heavy

576

Post top - direct to column

96227885 QCA3C4M

4m

14.9

76

0.51

0.46

0.41

0.31

96503703 QCA2C4M76

4m

14.9

76

0.44

0.40

0.36

0.27

96227886 QCA3C5M

5m

14.9

76

0.37

0.33

0.29

0.21

96227896 QCA2C5M76

5m

14.9

76

0.32

0.29

0.25

0.18

96227888 QCA3C6M

6m

14.9

76

0.27

0.23

0.20

0.13

96227898 QCA2C6M76

6m

14.9

76

0.24

0.21

0.18

0.12

96227847 QCA1C3M76

3m

14.9

76

0.73

0.66

0.59

0.45

96227923 QCA1C4M76

4m

14.9

76

0.44

0.39

0.34

0.23

96227925 QCA1C5M76

5m

14.9

76

0.37

0.33

0.29

0.21

Notes:

1. A standard signage of 0.3m

2

, 5kg and 2,500mm above ground level has been taken into account in the calculations. Columns or rows with values in bracket, ( ) denotes the maximum wind area, m

2

allowed with the standard signage removed.

2. All aluminium columns are designed to the European Standard BS EN40 which meets the requirements in the UK. Column capacities are provided in relation to Rationalised Wind Loading Regions and

Factors. These are defined in the EN40-3-3 Design and Verification by Calculations by the British Standards Institute (BSI) and the PD6547: 2004 National Application Document. From EN40, default

values of Terrain Category have been used, columns under 8m use Terrain Category III and columns 8m and above use Terrain Category II with a maximum site altitude of 250m from sea level.

3. Advice will be required if the location of the installation is:

Closer than 5km from the coast

Situated at an altitude greater than 250m from sea level

Subject to significant wind funnelling

Within the Shetland, Western Isles of Orkney administrative area.

4. All calculations have been completed assuming a design life of 50 years as opposed to the industry standard of 25 years.

Gamma/Legend Post Top

Post Top Ø76mm

Luminaire Mount

SAP Code Catalogue No.

Height

(m)

Luminaire

Maximum

Weight (kg)

Shaft diameter

(mm)

Luminaire MaximumWind Area m

2

for

Rationalised Wind Loading Factor, Rwf N/m

2

Light

396

Medium

429

Heavy

466

X Heavy

576

Post top - direct to column

96227885 QCA3C4M

4m

17.0

76

1.01

0.91

0.82

0.62

96503703 QCA2C4M76

4m

17.0

76

1.04

0.94

0.84

0.64

96227886 QCA3C5M

5m

17.0

76

0.56

0.50

0.44

0.31

96227896 QCA2C5M76

5m

17.0

76

0.65

0.58

0.51

0.37

96227888 QCA3C6M

6m

17.0

76

0.38

0.33

0.28

0.19

96227898 QCA2C6M76

6m

17.0

76

0.44

0.38

0.33

0.22

96227847 QCA1C3M76

3m

17.0

76

0.97

0.87

0.77

0.57

96227923 QCA1C4M76

4m

17.0

76

0.51

0.44

0.39

0.26

96227925 QCA1C5M76

5m

17.0

76

0.56

0.50

0.44

0.31

Note: 1. A standard signage of 0.3m

2

, 5kg and 2,500mm above ground level has been taken into account in the calculations.

Avenue

Post Top Ø60mm

Luminaire Mount

SAP Code Catalogue No.

Height

(m)

Luminaire

Maximum

Weight (kg)

Shaft diameter

(mm)

Luminaire MaximumWind Area m

2

for

Rationalised Wind Loading Factor, Rwf N/m

2

Light

396

Medium

429

Heavy

466

X Heavy

576

Post top - direct to column

96235757 QCA2C3M60

3m

34.2

60

0.73

0.65

0.57

00.41

Notes:

1. A standard signage of 0.3m

2

, 5kg and 2,500mm above ground level has been taken into account in the calculations.

2. All aluminium columns are designed to the European Standard BS EN40 which meets the requirements in the UK. Column capacities are provided in relation to Rationalised Wind Loading Regions and Factors. These

are defined in the EN40-3-3 Design and Verification by Calculations by the British Standards Institute (BSI) and the PD6547: 2004 National Application Document. From EN40, default values of Terrain Category

have been used, columns under 8m use Terrain Category III and columns 8m and above use Terrain Category II with a maximum site altitude of 250m from sea level.

3. Advice will be required if the location of the installation is:

Closer than 5km from the coast

Situated at an altitude greater than 250m from sea level

Subject to significant wind funnelling

Within the Shetland, Western Isles of Orkney administrative area.

4. All calculations have been completed assuming a design life of 50 years as opposed to the industry standard of 25 years.

www.thornlighting.co.uk