Call
OVERDOOR LIGHTS
NC806C
Overdoor light
NC806CS
Overdoor light with sounder
Overdoor lights use ultra-bright
LEDs for long-life and low current
consumption. Up to four zones
can indicate on one overdoor
light and they can be used in
conjunction with input expanders
for area/direction indicators at the end of corrdiors, etc.
CEILING PULLS
NC807C
Ceiling pull cord unit
RESET POINTS
NC809DB
Button reset point
NC809DM
Magnetic reset point
NC809DB
and
NC809DM
reset points
can be used for resetting ceiling pulls
and, if required, wall call points. They
should be sited out of reach of residents.
The NC809DB has a RESET button
whereas the NC809DM has a RESET target
which is operated by an NC803M Magnetic reset key.
SOUNDERS
NC887D
Switchable sounder
NC888D
Remote sounder
NC888D
Remote sounders use
low current beepers with an
insistent tone.
NC887D
Switchable sounders can be
switched off when not re-
quired. When OFF, a red light
shows as a warning and an orange light comes on if a call point
is activated (when ON a green light comes on when a call point
is activated). Each switchable sounder can control up to three
NC888D remote sounders. Relay contacts are provided at all
master and repeater panels (except emergency repeaters) to
operate other sounders, radio pagers, etc. if required.
MONITORING POINTS
NC894DKB
Isolatable button reset door monitoring point
NC894DKM
Isolatable magnetic reset door monitoring point
NC895DM
Magnetic reset doorbell point
STANDARD CALL POINTS
NC802DB
Button reset call point
NC802DM
Magnetic reset call point
NC802DB
call points incorporate a CALL
button, a confidence light, a remote
socket and a RESET button. The
NC802DM
call point looks the same but has a RESET
'target' instead of a RESET button, oper-
ated by an NC803M Magnetic reset key.
TAIL CALL LEADS
NC805C/6
6ft. Tail call button
NC805C/14
14 ft. Tail call button
NC805D
4–12 ft. Tail call button with coiled lead
Tail call leads consist of a pear
push, a lead and a right angled
jack plug to connect it to a call
point’s remote socket. A call is
made by pressing the pear push or
by pulling the plug out (to ensure
it cannot be accidentally removed without staff knowing about it).
HAND/FOOT OPERATED PNEUMATIC PADS
NC805P
Hand/foot operated pneumatic pad
NC805AS
Remote air switch
An
NC805P
pneumatic pad, when
used in conjunction with an
NC805AS
air switch, is ideal for
patients who find it difficult to
press buttons. Applying pressure
to the pad operates the highly-sensitive air switch which,
when connected to a call point’s remote socket, triggers a call.
PORTABLE MOVEMENT DETECTORS
NC805MD
Portable movement detector
ON
OFF
Call
The
NC805MD
is a simple to operate
adjustable weight sensor which sits
under the leg of a bed and connects
to a call point’s remote socket via
a jack plug. A call is triggered
when the bed is vacated, thus
alerting staff to the prospect of a wandering patient.
Ceiling pulls incorporate a confidence light, a
six foot cord and an open-sided triangular
pull for ease of use by the infirm. Four
knockouts are provided for 16 mm
square mini trunking (YT1) and the
backplate fits BESA centres. They
can be reset at a reset point or at a wall call point.
NC894DKB
s and
NC894DKM
s
have an isolation keyswitch,
confidence light and RESET
button or ‘target’. When a door
is opened a call is triggered.
Doorbell points connect to the
bell push wiring. The bell is powered by its own low voltage supply.
When the bell push is operated the bell rings normally and a call
is triggered on the system. Illuminated pushes cannot be used.
INPUT EXPANDERS
NC884
5:1 Input expander with 'pull up'
NC885
5:1 Input expander
Input expanders are used to give area
indication and have five inputs and one
output which can operate overdoor lights,
interface modules, or zone indicators
on a panel in another part of the
building. The outputs of several input
expanders can be connected together. Size 53mm x 25mm x 20mm.
Fix by self-adhesive pad. Contact the technical dept. for details.
INTERFACE MODULE
NC886C
Interface module
Interface modules switch a voltage output
(12VDC @ 500 mA max.) and connect like
overdoor lights. They can drive devices
such as sounders and, when used with
input expanders, give output flexibility for
any requirement. NB: The standard
nursecall power supply may not be able to power the
additional device. Contact the technical dept. for details.
Call
RESET
Call
CALLING
RESET
MONITORINGPOINT
RESET
Call
ON
ISOLATED
CALL
RESET
Call