TSC-0912 - 09.10.12
Electrical specification
ESP 240/I/TNS ESP 240/III/TNS ESP 240/I/TNC ESP 240/III/TNC ESP 240/I/TT ESP 240/III/TT
Nominal voltage - Phase-Neutral
U
o
(RMS)
240 V
Maximum voltage - Phase-Neutral
U
c
(RMS/DC)
320 V/420 V
Temporary Overvoltage TOV
U
T
1
350 V
Short circuit withstand capability
25 kA/50 Hz
Frequency range
47-63 Hz
Max. back-up fuse
(see installation instructions)
250 A
Leakage current
(to earth)
< 2.5 mA
< 2.5 mA
< 2.5 mA
< 2.5 mA
-
-
Volt free contact
- current rating
- nominal voltage
(RMS)
Screw terminal
0.5 A
250 V
Transient specification
ESP 240/I/TNS ESP 240/III/TNS ESP 240/I/TNC ESP 240/III/TNC ESP 240/I/TT ESP 240/III/TT
Type 1 (BS EN/EN), Class I (IEC)
Nominal discharge current 8/20 µs (per mode)
I
n
50 kA
25 kA
50 kA
25 kA 50 kA/100 kA (N-E) 25 kA/50 kA (N-E)
Let-through voltage
U
p at
I
n
2
< 1.5 kV
< 1.4 kV
< 1.5 kV
< 1.4 kV
< 1.5 kV
< 1.4 kV
Impulse discharge current 10/350 µs
I
imp
(per mode)
3
50 kA
25 kA
50 kA
25 kA
50 kA/100 kA
(N-E)
25 kA/50 kA
(N-E)
Let-through voltage
U
p at
I
imp
2
< 1.2 kV
< 1.2 kV
< 1.2 kV
< 1.2 kV
< 1.2 kV
< 1.2 kV
Let-through voltage
U
p at 1.2/50 µs
(N-E, TT system)
-
-
-
-
< 1.2 kV
< 1.2 kV
Type 2 (BS EN/EN), Class II (IEC)
Nominal discharge current 8/20 µs (per mode)
I
n
50 kA
25 kA
50 kA
25 kA 50 kA/100 kA (N-E) 25 kA/50 kA (N-E)
Let-through voltage
U
p at
I
n
2
< 1.5 kV
< 1.4 kV
< 1.5 kV
< 1.4 kV
< 1.5 kV
< 1.4 kV
Maximum discharge current
I
max (per mode)
3
100 kA
100 kA
100 kA
100 kA 100 kA/160 kA
(N-E)
100 kA/100 kA
(N-E)
Mechanical specification
ESP 240/I/TNS ESP 240/III/TNS ESP 240/I/TNC ESP 240/III/TNC ESP 240/I/TT ESP 240/III/TT
Temperature range
-40 to +80 °C
Connection type
Screw terminal
Conductor size
(stranded)
25 mm
2
Earth connection
Screw terminal
Volt free contact
Connect via screw terminal with conductor up to 1.5 mm
2
(stranded)
Degree of protection
(IEC 60529)
IP20
Case material
Thermoplastic, UL 94 V-0
Mounting
Indoor, 35 mm top hat DIN rail
Weight -
unit
0.84 kg
0.44 kg
0.44 kg
0.29 kg
0.68 kg
0.44 kg
-
packaged
0.94 kg
0.54 kg
0.54 kg
0.39 kg
0.78 kg
0.54 kg
Dimensions
to DIN 43880 - HxDxW
4
90 mm x 68 mm
x 72 mm (4TE)
90 mm x 68 mm
x 36 mm (2TE)
90 mm x 68 mm
x 36 mm (2TE)
90 mm x 68 mm
x 36 mm (2TE)
90 mm x 68 mm
x 72 mm (4TE)
90 mm x 68 mm
x 54 mm (3TE)
72 mm
ESP 240/I/TNS
ESP 240/I/TT
54 mm
ESP 240/III/TT
36 mm
90 mm
ESP 240/III/TNS
ESP240/I/TNC
ESP240/III/TNC
45 mm
51 mm
Standard
depth
68 mm
Technical specification
1
Temporary Overvoltage rating is for a maximum duration of
5 seconds tested to BS EN/EN/IEC 61643.
2
The maximum transient voltage let-through of the protector
throughout the test, phase to earth and neutral to earth.
3
The electrical system, external to the unit, may constrain the
actual current rating achieved in a particular installation.
4
The remote signal contact (removable) adds 10 mm
to height.