Technical

information

Ventilation

Example 1

Example 2

Room

Bathroom

Room

Kitchen

Volume

2.0 x 2.0 x 2.0 = 8m

3

Volume

2.8 x 2.8 x 2.8 = 22m

3

Number of air changes

required

3

Number of air

changes required

10

Performance

8 x 3 = 24m

3

/h

Performance

22 x 10 = 220m

3

/h

Fan required

GFAN4 = 93m

3

/h

Fan required

GFAN6 = 250m

3

/h

Stale air is also removed by installing the appropriate GET fan. In certain circumstances, such as in toilets, a timer is incorporated to provide

an automatic turn-on period of up to 25 minutes as stipulated in The Building Regulations.

Recommended minimum number of air changes in certain environments

Environment

Changes per hour Environment

Changes per hour Environment

Changes per hour

Bathrooms and

shower rooms

3

Halls and landings

3

Shops

8

Bedrooms

2

Hospital rooms

4

Sports facilities

6

Cafés

10

Kitchens (domestic)

10

Store rooms

3

Canteens

8

Laundries and

launderettes

10

Toilets (domestic)

3

Cellars

3

Living and other

domestic rooms

3

Toilets (public)

10

Changing rooms with

showers

15

Meeting rooms

4

Utility rooms

15

Conference rooms

8

Offices

6

Workshops

6

Garages

6

Restaurants & bars

6

Hairdressing salons

10

School rooms

2

Standard 4”

100mm

Standard 4”

100mm

slimline

Premium

4” 100mm

slimline

4” 100mm

panel

Premium 6”

150mm

Voltage Supply

220 - 240V 50Hz 230V - 50Hz

220 - 240V 50Hz 220 - 240V 50Hz 220 - 240V 50Hz

Power

20W Max

26W Max

16W

16W

26W

Timer Control (where applicable)

3 - 25 mins

3 - 25 mins

1 - 25 mins

1 - 25 mins

1 - 25 mins

Humidistat Timer Control (where applicable) 3 - 50 mins

1 - 50 mins

1 - 25 mins

1 - 25 mins

1 - 25 mins

Extract Capacity

93

3

/hr max

250

3

/hr max

129

3

/hr

115

3

/hr

295

3

/hr

Humidity Adjustment

50 - 60% 50 - 90% 60 - 90% 60 - 90% 60 - 90%

Noise Level

45dB

35dB

37dB

36dB

39dB

IP Rating

IPX4

IPX4

IP24

IP24

IP24

Max. Room Temperature

40°C

40°C

45°C

45°C

45°C

Double Insulated

yes

yes

yes

yes

yes

Fitted with Fused Thermal Protection

yes

yes

yes

yes

yes

155mm

12mm

Ø 100mm

155mm

30mm

112mm

Ø 150.6mm

212mm

Standard 4” (100mm)

Standard 6” (150mm)

Standard 4” (100mm) slimline

Dimensions

Part number

A

B

C

D

GPGPTFAN4TB

Designer Range

126

32

100

170

GSPTFAN4T

Premium Range

126

30

100

150

GSPTFAN4LT

Aluminium Panel

126

30

100

150

D

B

C

A