188
Technical
information
Lighting
Lighting range standards
Mains halogen
downlighters
Low voltage
dichroic
downlighters
Low voltage
cabinet
lights
Operating voltage
230/240V AC 50Hz
12V AC 50Hz
12V AC 50Hz
Max lamp rating
50W
50W
20W
Standard compliance
EN 60598-1:1997
EN 60598-1:1997
EN 60598-1:1997
Lamp type
GU10 closed halogen
ES50
MR16 dichroic
closed type
G4 capsule lamp
Beam diagrams
Halogen lamps (mains)
MR16 dichroic lamps (low voltage)
LUX AT BEAM CENTRE SPOT Ø IN METRES
750
0.69
1.38
2.07
2.75
190
85
45
1350
340
150
85
1m
2m
3m
4m
12V Dichroic
20W 35W
GX5.3
38º BEAM
LUX AT BEAMCENTRE SPOT Ø IN METRES
2200
0.69
1.38
2.07
2.75
550
245
140
1m
2m
3m
4m
12V Dichroic
50W
GX5.3
38º BEAM
Electronic transformer data
65VA
105VA
150VA
200VA
Model
GTRE65P GTRE65 GTRE105P GTRE105 GTRE150P GTRE150 GTRE200P GTRE200
Primary (V)
230-240V
230-240V
230-240V
230-240V
Secondary (V)
11.4 - 11.6V
11.4 - 11.6V
11.4 - 11.6V
11.4 - 11.6V
Power
65VA
105VA
150VA
200VA
Output (Hz)
40KHz - 43KHz
40KHz - 43KHz
40KHz - 43KHz
40KHz - 43KHz
Current (A)
5.4A
8.8A
13A
17.4A
LED Indicator
Yes
No
Yes
No
Yes
No
Yes
No
Output wires
2 x 300mm silicon insulated
2 Pairs
4 Pairs
4 Pairs
Short Circuit
Protection
Manual Reset Auto Reset Manual Reset Auto Reset Manual Reset Auto Reset Manual Reset Auto Reset
Overload Protection Manual Reset Auto Reset Manual Reset Auto Reset Manual Reset Auto Reset Manual Reset Auto Reset
Thermal Protection Resettable
Yes
Resettable
Yes
Resettable
Yes
Resettable
Yes
Max Case Temp
85˚C
85˚C
85˚C
85˚C
Power Factor
0.98
0.98
0.98
0.98
Cable Size max.
1.5mm
2
1.5mm
2
1.5mm
2
1.5mm
2
Max Dimensions
124mm x 30mm x 40mm 147mm x 30mm x 40mm 206mm x 44mm x 56mm 206mm x 44mm x 56mm
Case material
Polycarbonate UL94 V0
Polycarbonate UL94 V0
Polycarbonate UL94 V0
Polycarbonate UL94 V0
Weight
107g
97g
121g
112g 280g
270g
300g
290g
Guarantee
10 Years
5 Years
10 Years
5 Years 10 Years
5 Years
10 Years
5 Years
LUX AT BEAMCENTRE SPOT Ø IN METRES
2200
0.69
1.38
2.07
2.75
550
245
140
1m
2m
3m
4m
12V Dichroic
50W
GX5.3
38º BEAM