Table of Contents Table of Contents
Previous Page  37 / 210 Next Page
Information
Show Menu
Previous Page 37 / 210 Next Page
Page Background

37

CompactNSX100/250

verticalmounting

Functional system

Functional units

Circuit breakers

Mounting

Vertical fixed

600

300

DD383871.eps

DD380666.eps

Devices

Toggle

Rotary handle

NSX100/160 NSX250 Vigi NSX100/160 Vigi NSX250 NSX100/160 NSX250 Vigi NSX100/160 Vigi NSX250

Number of devices per row 4 x 3P or 3 x 4P

4 x 3P or 3 x 4P

Nb. of vertical modules

7

9

8

11

7

9

8

11

Mounting plates

03040

03040 03040

03040

03041

03041 03041

03041

Front plates

[Nb. of vertical

modules]

cut-out

03243

[5]

03243

[5]

03241

[7]

03241

[7]

03243

[5]

03243

[5]

03244

[7]

+ LV429285

(collar)

03244

[7]

+ LV429285

(collar)

upstream -

03802

[2]

-

03802

[2]

-

03802

[2]

-

03802

[2]

downstream

03802

[2]

03802

[2]

03801

[1]

03802

[2]

03802

[2]

03802

[2]

03801

[1]

03802

[2]

Upstream connection

Long terminal shields

3P:

LV429517

4P:

LV429518

Cable-ties

08867

+

08866

Divisible

blanking plates

(H x L)

85 x 147 mm

03249

(to add modular devices to a row with Compact NSX 3P or 4P without electronic trip unit)

107 x 147 mm

03222

(to add modular devices to a row with Compact NSX 3P or 4P with electronic trip unit)

46 x 1000 mm

03220

(to add modular devices to a row with Compact NSX 3P or 4P + Vigi without electronic trip unit)

46 x 90 mm

(1)

03221

(to add modular devices to a row with Compact NSX 3P or 4P + Vigi with electronic trip unit) - Set of 4

(1)

In strip.

Downstream distribution Linergy DP 250 A

distribution block

Insulated Linergy BW busbars

(2)

Rear Linergy BS

busbars

Linergy BS multi-stage

busbars

DD380780.eps

DD380593.eps

DD380777.eps

DD380761.eps

Type of connected devices All types

NSX

Vigi NSX

All types

All types

Distribution block / busbars

3P:

04033

4P:

04034

+

03002

> page 92 > page 84

> page 86

> page 87, 88

Power supply block

-

04061

04061

-

Connection block

-

04062

must be made must be made

Short terminal shields

-

3P:

LV429515

4P:

LV429516

3P:

LV429517

4P:

LV429518

3P:

LV429517

4P:

LV429518

(2)

1 device centred on mounting plate.

Downstream

distribution

Linergy DP

250 A

distribution

block in duct

Insulated Linergy

BW busbars

(3)

Rear Linergy

BS busbars

Linergy BS

multi-stage

busbars or multi-

stage distribution

block

DD380745.eps

Dd382567.eps

DD380777.eps

Dd382305.eps

Type of

connected

devices

All types

NSX Vigi NSX All types

All types

Distribution

block / busbars

3P:

04033

4P:

04034

+

03011

> page  92

> page 84

> page 86

> page 87, 88

Power supply

block

-

04061 04061

-

-

Connection

block

-

04064

must be

made

must be made

04065

Short/long

terminal

shields

-

3P:

LV429515

4P:

LV429516

3P:

LV429517

4P:

LV429518

3P:

LV429517

4P:

LV429518

3P:

LV429515

4P:

LV429516

(3)

Space available at the top of the enclosure after mounting the universal power supply block:

- NSX100/250 = 7 modules

- Vigi NSX100/250 = 9 modules.

Space required by power supply block on Linergy BW busbars = 5 modules.

Mounting

Vertical fixed

300

600

DD383858.eps

Devices

Toggle

Direct

rotary

handle

NSX

100/250

Vigi NSX

100/250

NSX

100/250

Number of devices

per row

1

1

1

Nb. of vertical modules

9

13

9

Mounting plates

03050 03050 03051

Front plates

[Nb. of

vertical

modules]

cut-out

03253

[9]

03293

[9]

03253

[9]

upstream -

03812

[2]

-

downstream -

03812

[2]

-

Upstream connection

Long terminal shields 3P:

LV429517

4P:

LV429518

Cable-ties

08868

+

08866