Easypact CVS100/250

verticalmounting

Functional system

Functional units

Mounting

Vertical fixed without cable duct

600

300

DD383871.eps

DD385265.eps

Devices

Toggle

Rotary handle

CVS100/250

Vigi CVS100/250

CVS100/250

Vigi CVS100/250

Number of devices per row 4 x 3P or 3 x 4P

4 x 3P or 3 x 4P

4 x 3P or 3 x 4P

4 x 3P or 3 x 4P

Nb. of vertical modules

9

11

9

11

Mounting plates

03040

03040

03041

03041

Front plates

[Nb. of vertical

modules]

cut-out

03243

[5]

03241

[7]

03243

[5]

03244

[7]

+ collar

LV429285

upstream

03802

[2]

03802

[2]

03802

[2]

03802

[2]

downstream

03802

[2]

03802

[2]

03802

[2]

03802

[2]

Upstream connection

Long terminal shields

3P:

LV429517

4P:

LV429518

3P:

LV429517

4P:

LV429518

3P:

LV429517

4P:

LV429518

3P:

LV429517

4P:

LV429518

Cable-ties

08867

+

08866

Divisible blanking plates

03249

03221

03249

03221

Downstream distribution Linergy DP 250 A

distribution block

Insulated Linergy BW busbars

(2)

Rear Linergy BS

busbars

Linergy BS multi-stage

busbars

DD380780.eps

DD380593.eps

DD380777.eps

DD380761.eps

Type of connected devices All types

CVS

Vigi CVS

All types

All types

Distribution block / busbars

3P:

04033

> page 92

4P:

04034

+

03002

> page 84

> page 86

> page 87, 88

Power supply block

-

04061

04061

-

Connection block

-

04062

must be made must be made

Short/long terminal shields

-

3P:

LV429515

4P:

LV429516

3P:

LV429517

4P:

LV429518

3P:

LV429517

4P:

LV429518

(1)

1 device centred on mounting plate.

Circuit breakers

Mounting Vertical fixed in duct

300

600

DD385266.eps

DD383858.eps

Devices

Toggle

Rotary handle

CVS100/250,

3P/4P

Vigi

CVS100/250,

3P/4P

CVS100/250,

3P/4P

Number of devices

per row

1

1

1

Nb. of vertical

modules

9

13

9

Mounting plates

03050

03050

03051

Front

plates

[Nb. of

vertical

modules]

cut-out

03250

[9]

03252

[11]

03253

[9]

upstream

-

03812

[2]

-

Upstream connection

Long terminal

shields

3P:

LV429517

4P:

LV429518

3P:

LV429517

4P:

LV429518

3P:

LV429517

4P:

LV429518

Cable-ties

08866 + 08868

Downstream

distribution

Linergy DP

250 A

distribution

block in duct

Insulated Linergy

BW busbars

(2)

Rear Linergy

BS busbars

Linergy BS

multi-stage

busbars or

multi-stage

distribution

block

DD380745.eps

Dd382567.eps

DD380777.eps

Dd382305.eps

Type of

connected

switchgear

All types CVS Vigi CVS All types

All types

Distribution

block / busbars

3P:

04033

4P:

04034

+

03011

> page 92

> page 84

> page 86

> page 87,

88

Power supply

block

-

04061 04061

-

-

Connection

block

-

04064

must be

made

must be made

04065

Short/long

terminal

shields

-

3P:

LV429515

4P:

LV429516

3P:

LV429517

4P:

LV429518

3P:

LV429517

4P:

LV429518

3P:

LV429515

4P:

LV429516

(2)

Space available at the top of the enclosure after mounting the universal power supply

block:

- CVS100/250 = 7 modules

- Vigi CVS100/250 = 9 modules

Space required by power supply block on insulated Linergy BW busbars = 5 modules.