43
Easypact CVS100/250
verticalmounting
Functional system
Functional units
Mounting
Vertical fixed without cable duct
600
300
DD383871.eps
DD385265.eps
Devices
Toggle
Rotary handle
CVS100/250
Vigi CVS100/250
CVS100/250
Vigi CVS100/250
Number of devices per row 4 x 3P or 3 x 4P
4 x 3P or 3 x 4P
4 x 3P or 3 x 4P
4 x 3P or 3 x 4P
Nb. of vertical modules
9
11
9
11
Mounting plates
03040
03040
03041
03041
Front plates
[Nb. of vertical
modules]
cut-out
03243
[5]
03241
[7]
03243
[5]
03244
[7]
+ collar
LV429285
upstream
03802
[2]
03802
[2]
03802
[2]
03802
[2]
downstream
03802
[2]
03802
[2]
03802
[2]
03802
[2]
Upstream connection
Long terminal shields
3P:
LV429517
4P:
LV429518
3P:
LV429517
4P:
LV429518
3P:
LV429517
4P:
LV429518
3P:
LV429517
4P:
LV429518
Cable-ties
08867
+
08866
Divisible blanking plates
03249
03221
03249
03221
Downstream distribution Linergy DP 250 A
distribution block
Insulated Linergy BW busbars
(2)
Rear Linergy BS
busbars
Linergy BS multi-stage
busbars
DD380780.eps
DD380593.eps
DD380777.eps
DD380761.eps
Type of connected devices All types
CVS
Vigi CVS
All types
All types
Distribution block / busbars
3P:
04033
> page 92
4P:
04034
+
03002
> page 84
> page 86
> page 87, 88
Power supply block
-
04061
04061
-
Connection block
-
04062
must be made must be made
Short/long terminal shields
-
3P:
LV429515
4P:
LV429516
3P:
LV429517
4P:
LV429518
3P:
LV429517
4P:
LV429518
(1)
1 device centred on mounting plate.
Circuit breakers
Mounting Vertical fixed in duct
300
600
DD385266.eps
DD383858.eps
Devices
Toggle
Rotary handle
CVS100/250,
3P/4P
Vigi
CVS100/250,
3P/4P
CVS100/250,
3P/4P
Number of devices
per row
1
1
1
Nb. of vertical
modules
9
13
9
Mounting plates
03050
03050
03051
Front
plates
[Nb. of
vertical
modules]
cut-out
03250
[9]
03252
[11]
03253
[9]
upstream
-
03812
[2]
-
Upstream connection
Long terminal
shields
3P:
LV429517
4P:
LV429518
3P:
LV429517
4P:
LV429518
3P:
LV429517
4P:
LV429518
Cable-ties
08866 + 08868
Downstream
distribution
Linergy DP
250 A
distribution
block in duct
Insulated Linergy
BW busbars
(2)
Rear Linergy
BS busbars
Linergy BS
multi-stage
busbars or
multi-stage
distribution
block
DD380745.eps
Dd382567.eps
DD380777.eps
Dd382305.eps
Type of
connected
switchgear
All types CVS Vigi CVS All types
All types
Distribution
block / busbars
3P:
04033
4P:
04034
+
03011
> page 92
> page 84
> page 86
> page 87,
88
Power supply
block
-
04061 04061
-
-
Connection
block
-
04064
must be
made
must be made
04065
Short/long
terminal
shields
-
3P:
LV429515
4P:
LV429516
3P:
LV429517
4P:
LV429518
3P:
LV429517
4P:
LV429518
3P:
LV429515
4P:
LV429516
(2)
Space available at the top of the enclosure after mounting the universal power supply
block:
- CVS100/250 = 7 modules
- Vigi CVS100/250 = 9 modules
Space required by power supply block on insulated Linergy BW busbars = 5 modules.