Accessories

Description

For enclosure installation

n

Association kit: used for horizontal or vertical association of two enclosures with

one another while preserving IP65

n

Wall mounting lugs: used to fix the enclosure to the wall without using holes in

the back of the enclosure

n

Row separator: used to create IP2 insulated zones. For example: separate strong

and weak current zones

n

Jack-up block: used to detach the enclosure from the wall in order to route

cables behind the enclosure (2 lengths of 1 metre to be cut)

n

Plain front plate: used to hide a zone without modular switchgear

n

Blanking plate: clipped onto the front plates to conceal slots with no devices

n

Junction for trunking: allows tidy incoming of cables in a trunking

For switchgear installation

n

Functional plates for 90 x 100 mm slot:

Adaptation (screwed on) for 65 x 85 mm power outlets

Blanking or adaptation (screwed on) for 65 x 65 mm or 75 x 75 mm power

outlets (slot to be punched out)

Blanking or adaptation (clipped on) for buttons, indicator lights and switches of

diameters 16 and 22 mm (1 central slot or 2 side by side to punch out).

Blanking for identification (clipped on)

n

Functional plates for 103 x 225 mm slot:

Adaptation (screwed on) with 2 openings: 65 x 85 mm and 90 x 100 mm.

Blanking or adaptation (screwed on) offering 1 slot for 65 x 65 mm or

75 x 75 mm power outlets (to be punched out) and a universal zone

Adaptation (screwed in) for 63 A 100 x 107 mm LV power outlet

n

Interface kit for 90 x 100 mm slot for:

INS40 to 80 A (chassis + plate)

Modular switchgear up to 4 modules

e.g. residual current circuit breaker (chassis + plate + membrane)

n

Slotted plate (150 x 250 mm): screwed onto the back of the enclosure, used to

fix non-modular devices

For electrical connection

n

Terminal block support: flat iron (12 x 2 mm), 2 versions: screwed onto the pins

or onto the chassis

n

Set of insulated terminal blocks with IP42 covers:

4 holes: clipped onto the terminal block supports, fixed onto walls by dovetails,

8 holes: clipped onto the terminal block supports, clipped onto DIN symmetrical

rail, screwed onto the back

32 holes: clipped onto the terminal block supports

n

Wiring strap: used to guide cables along walls for simplified cabling (set of 5)

n

Cable support sleeves: used for incoming flexible cables

n

Cable glands: used for cable and tube incoming, guaranteeing tightness and

mechanical withstand

For identification

n

Self-adhesive symbol: allows identification of feeders by symbols:

Currents: loads (power outlet, lighting, convector, etc.), places (bedroom,

bathroom, etc.)

Special: loads (surge arrester, gate, swimming pool, etc.), places (technical

room, computer room, etc.)

n

Self-adhesive sheets for SISmarker printing: allows printing of customised labels

using the SISmarker software

For enclosure protection

n

Sealing kit: used to seal the front face on the back (2 screws) and the front

plates on the front face (4 kits)

n

Keylock: Eurolocks combination no. 850. Installed in the door

n

Insert (male square or triangle, female key supplied): installed in the door

For enclosure maintenance

n

Front plate

n

Chassis 1 row: can be combined to obtain a multi row chassis

Terminal block composition

Number of

holes

Total

Width

in mm

Cross section in mm

2

10

16

4

2

2

85

8

4

4

85

32

16

16

202

10/32